MAINTENANCE INSTRUCTIONS

TROUBLE-SHOOTING GUIDE (continued)

PROBLEM

POSSIBLE CAUSE

SOLUTION

 

1.

Fuse

1.

Replace

 

2.

Control

2.

Replace

Cabinet does not heat, or doesn’t heat

3. Sensor

3.

Replace

properly

4. Heater contactor

4.

Replace

 

5.

Loose wiring at heater contactor

5.

Replace

 

6.

On/Off Switch

6.

Replace

 

 

 

 

 

 

1.

On/Off Switch

1.

Replace

Blowers do not operate

2.

Fuse

2.

Replace

3.

Blower

3.

Replace

 

 

4.

Control

4.

Replace

 

 

 

 

Heater will not shut off

1. Control defective

1.

Replace

 

 

 

 

 

 

1.

Vent fan switch defective

1.

Replace

Vent fans do not shut off

2.

Wait until it cools

2.

Control compartment is still hot.

 

Check “Heaters will not shutoff”

 

 

 

 

1.

Fuse

1.

Replace

Vent fans do not operate (See Note)

2. Vent fan switch defective

2.

Replace

 

3.

Vent fan defective

3.

Replace

 

 

 

 

Control will not switch from “COOK” to

1. Oven is in “PROBE” mode.

1.

Switch to “TIMED” mode

“HOLD” (timer mode)

2. Control defective

2.

Replace

 

 

 

 

 

Control will not switch from “COOK” to

1.

Oven is in the “TIMED” mode

1.

Switch to “PROBE” mode

2.

Probe not plugged in

2.

Plug in probe

“HOLD” (probe mode)

3.

Control defective

3.

Replace

 

 

 

 

 

 

 

1.

Oven in “TIMED” mode

1.

Switch to “PROBE” mode

Control will not switch to “COOK” (probe

2.

Probe temperature setting lower than

2.

Set probe temperature to desired

probe temperature

temperature

mode)

3.

Probe not plugged in

3.

Plug in probe

 

 

4.

Control defective

4.

Replace

 

 

 

 

 

NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement of electrical components must be done by a qualified electrician.

Refer to our Service Agency list, FL-1400(found in the back of this manual), of authorized service centers. Instructions for replacing parts are included in replacement parts list.

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

Page 7
Image 7
Cres Cor CO151H189B-Q1 manual TROUBLE-SHOOTINGGUIDE continued, Page 7 of, Maintenance Instructions, Heisley Road Mentor, OH