5925 Heisley Road • Mentor, OH
Ovens with | |
Microprocessor controls | |
Rev. 8 (10/06) | Page 7 of 13 |
|
|
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE (continued)
PROBLEM | POSSIBLE CAUSE | SOLUTION | |||
| 1. | Fuse | 1. | Replace | |
| 2. | Control | 2. | Replace | |
Cabinet does not heat, or doesn’t heat | 3. Sensor | 3. | Replace | ||
properly | 4. Heater contactor | 4. | Replace | ||
| 5. | Loose wiring at heater contactor | 5. | Replace | |
| 6. | On/Off Switch | 6. | Replace | |
|
|
|
|
| |
| 1. | On/Off Switch | 1. | Replace | |
Blowers do not operate | 2. | Fuse | 2. | Replace | |
3. | Blower | 3. | Replace | ||
| |||||
| 4. | Control | 4. | Replace | |
|
|
|
| ||
Heater will not shut off | 1. Control defective | 1. | Replace | ||
|
|
|
|
| |
| 1. | Vent fan switch defective | 1. | Replace | |
Vent fans do not shut off | 2. | Wait until it cools | |||
2. | Control compartment is still hot. | ||||
| Check “Heaters will not shutoff” | ||||
|
|
| |||
| 1. | Fuse | 1. | Replace | |
Vent fans do not operate (See Note) | 2. Vent fan switch defective | 2. | Replace | ||
| 3. | Vent fan defective | 3. | Replace | |
|
|
|
| ||
Control will not switch from “COOK” to | 1. Oven is in “PROBE” mode. | 1. | Switch to “TIMED” mode | ||
“HOLD” (timer mode) | 2. Control defective | 2. | Replace | ||
|
|
|
|
| |
Control will not switch from “COOK” to | 1. | Oven is in the “TIMED” mode | 1. | Switch to “PROBE” mode | |
2. | Probe not plugged in | 2. | Plug in probe | ||
“HOLD” (probe mode) | |||||
3. | Control defective | 3. | Replace | ||
| |||||
|
|
|
|
| |
| 1. | Oven in “TIMED” mode | 1. | Switch to “PROBE” mode | |
Control will not switch to “COOK” (probe | 2. | Probe temperature setting lower than | 2. | Set probe temperature to desired | |
probe temperature | temperature | ||||
mode) | |||||
3. | Probe not plugged in | 3. | Plug in probe | ||
| |||||
| 4. | Control defective | 4. | Replace | |
|
|
|
|
|
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures. Replacement of electrical components must be done by a qualified electrician.
Refer to our Service Agency list,
Call