5925 Heisley Road • Mentor, OH
Ovens | |
|
|
Rev. 10 (4/08) | Page 3 of 13 |
|
|
INSTALLATION INSTRUCTIONS
VENTING YOUR OVEN:
1.The purpose of ventilating hoods is to direct and capture smoke,
2.Low temperature equipment (maximum temperature 250°F/121°C) does not produce heat, odors, fumes,
3.Most jurisdictions consider our
4.Installation must conform with local codes. The authority having jurisdiction of enforcement of the codes will have the responsibility for making interpretations of the rules.
UNIT SPECIFICATIONS: All units use three (3) elements (2670 watts each).
All units are rated 8200 watts. Water units have one (1) immersion element (1850 watts).
MODEL NOS. | ELECTRICAL SPECS | ELEC. LOAD | POWER SUPPLY REQUIREMENT | |||||||
(AC SERVICE) | ALL 3 PHASE IS 3 WIRE + GROUND | |||||||||
|
|
| ||||||||
CONVECTION OVENS | Volts | Ph | Hz. | Amps | Volts | Amps | Ph | Volts | NEMA | |
CO151FWUA12B2081 | 208 | 1 | 60 | 39 | 208 | 50 | 1 | 208 | ||
CO151FWUA12B2401 | 240 | 1 | 60 | 34 | 240 | 50 | 1 | 240 | ||
CO151FWUA12B2083 | 208 | 3 | 60 | 23 | 208 | 30 | 3 | 208 | ||
CO151FWUA12B2403 | 240 | 3 | 60 | 20 | 240 | 30 | 3 | 240 | ||
RETHERM OVENS |
|
|
|
|
|
|
|
|
| |
RO151FWUA18B2081 | 208 | 1 | 60 | 39 | 208 | 50 | 1 | 208 | ||
RO151FWUA18B2401 | 240 | 1 | 60 | 34 | 240 | 50 | 1 | 240 | ||
RO151FWUA18B2083 | 208 | 3 | 60 | 23 | 208 | 30 | 3 | 208 | ||
RO151FWUA18B2403 | 240 | 3 | 60 | 20 | 240 | 30 | 3 | 240 | ||
RO151FW1332B2081 | 208 | 1 | 60 | 39 | 208 | 50 | 1 | 208 | ||
RO151FW1332B2401 | 240 | 1 | 60 | 34 | 240 | 50 | 1 | 240 | ||
RO151FW1332B2083 | 208 | 3 | 60 | 23 | 208 | 30 | 3 | 208 | ||
RO151FW1332B2403 | 240 | 3 | 60 | 20 | 240 | 30 | 3 | 240 | ||
|
| |||||||||
CO151HWUA6B2081 | 208 | 1 | 60 | 24 | 208 | 30 | 1 | 208 | ||
CO151HWUA6B2401 | 240 | 1 | 60 | 21 | 240 | 30 | 1 | 240 | ||
CO151HWUA6B2083 | 208 | 3 | 60 | 15 | 208 | 20 | 3 | 208 | ||
CO151HWUA6B2403 | 240 | 3 | 60 | 13 | 240 | 20 | 3 | 240 | ||
CO151XWUA5B2081 | 208 | 1 | 60 | 24 | 208 | 30 | 1 | 208 | ||
CO151XWUA5B2401 | 240 | 1 | 60 | 21 | 240 | 30 | 1 | 240 | ||
CO151XWUA5B2083 | 208 | 3 | 60 | 15 | 208 | 20 | 3 | 208 | ||
CO151XWUA5B2403 | 240 | 3 | 60 | 13 | 240 | 20 | 3 | 240 |
All models are designed for AC Service. Model numbers may have the letters: P, L, M, Z or S.
Call