5protection features

CPXTM owner’s manual

turn-on/turn-off protection

At power-up, the amplifier stays in the protect mode with outputs disconnected for approximately six seconds while the power supplies charge and stabilize. While the output relays are open, the GCL™ LEDs light.When power is removed, the speaker loads immediately disconnect so that no thumps or pops are heard.

AUTORAMPsignal control

Whenever a CPX Series amplifier powers up or comes out of a protect mode, the AUTORAMP circuit acti- vates. While the speakers are disconnected, the AUTORAMP circuit fully attenuates the signal and activates the GCL LED. After the output relay closes, the signal slowly and gradually raises to its set level.The PWR LED will illuminate and the GCL LED will turn off when the signal is no longer attenuated.The AUTORAMP Signal Control circuit has some important advantages over conventional instant-on circuits:

1.If a signal is present during power-up (or when coming out of protect), the speakers are spared a sudden, potentially damaging burst of audio power.

2.Because the gain is reduced until after the output relay closes, no arcing occurs at the contacts.This extends the contacts’ useful life.

p.26

Page 26
Image 26
Crest Audio CPX 3800 owner manual Turn-on/turn-off protection, Autoramp signal control