Ethernet OEM Module Crestron eServer™
File System Commands
These commands (dir, del, xputfile, free, initialize, and type) are available for
executing file system commands. There is no need to use these commands via the
setup menus since they are duplicated in Crestron software tools.
SIMPL+ Commands
These commands (forth, newSIMPL, pause, and resume) are available for executing
SIMPL+ commands. There is no need to use these commands via the setup menus
since they are duplicated in SIMPL+.
Programming with SIMPL™ Windows To implement the eServer in a Crestron CNX control system, use a SIMPL Windows
program (drop the CEN-OEM definition from the Ethernet Devices folder in
Configuration Manager). The eServer definition can be found in the Ethernet Control
Modules folder in the Device Library. The CEN-OEM, like any other device that is
controlled via Ethernet from a Crestron control system, gets an IP ID and an entry in
the IP Table of the control system. Refer to "ip_adr" on page 15 for setting the CEN-
OEM IP ID. For details about the IP Table, refer to "Add_master" on page 14.
Use of the CEN-OEM symbol is necessary to incorporate the eServer functionality in
a Crestron CNX control system. The SIMPL+ program or module that complements
the SIMPL Windows program with eServer symbol is necessary to program the
eServer itself.
CEN-OEM Symbol
The interface to the CEN-OEM symbol in Program Manager looks like the symbol
for a touchpanel. There are digital input/output lists, analog input/output lists, and
serial input/output lists. The figure after this paragraph illustrates the CEN-OEM
digital symbol as it appears in the Detail View of Program Manager.
CEN-OEM Symbol
SIMPL+ Interface
The following table shows how the SIMPL+ program inside the CEN-OEM
interprets data routed into and out of the symbol.
20 • Ethernet OEM Module: eServer™ Operations Guide - DOC. 8148