Crosley W10151585B manual Location Requirements, You will need, Installation Clearances, Ab C

Models: W10151585B

1 16
Download 16 pages 3.86 Kb
Page 4
Image 4
Location Requirements

Location Requirements

You will need

A location that allows for proper exhaust installation. See “Venting Requirements.”

A 120-volt, 60-Hz., AC-only, 15- or 20-amp circuit.

A grounded electrical outlet located within 2 ft (610 mm) of either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the dryer weight (dryer and load) of 115 lbs (52 kg). The combined weight of a companion appliance should also be considered.

A level floor with a maximum slope of 1" (25 mm) under entire dryer.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. Drying times can be extended.

Minimum spacing for recessed area and closet installation

The following dimensions shown are for the minimum spacing allowed when the dryer is to be operated with, or without, the Stack Stand Kit. To purchase a Stack Stand Kit, see “Assistance or Service.”

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, and floor moldings.

Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer.

For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Recessed or closet installation - Dryer only

14"*

 

 

(356 mm)

 

 

 

18"* (457 mm)

 

3"*

1"

1"

(76 mm)

(25 mm)

(25 mm)

A

B

 

A. Side view - closet or confined area

B. Recessed area

Recessed or closet installation - Stacked

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes, or sleeping quarters. Contact your local building inspector.

Installation Clearances

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

*20 3 4" You will need (527 mm)

12"*

3"*

(305 mm)

(76 mm)

 

DRYER

12"*

 

(305 mm)

 

 

WASHER

1"

 

 

 

 

 

 

 

 

 

 

 

1" 1"*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(25 mm)

 

 

 

 

 

(25 mm) (25 mm)

 

48 in.2* (309.7 cm2)

24in.2 *

(154.8 cm2)

Minimum spacing for recessed area and closet installation 3"* (76 mm)

Recessed or closet installation - Dryer only 3"* (76 mm)

31"

(787 mm)

23 7 8"

(606 mm)

†Height with caster is 32½" (826 mm)

*Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbows. See “Venting Requirements.”

AB C

A. Recessed area

B. Side view - closet or confined area

C. Closet door with vents

Mobile Home - Additional Location Requirements

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 245, HUD Part 280) or Standard CAN/CSA-Z240 MH.

4

Page 4
Image 4
Crosley W10151585B Location Requirements, You will need, Minimum spacing for recessed area and closet installation, Ab C