Commercial Audio Series
2 Setup
2.1 Installation
CAUTION: Before you begin, make sure your
Use a standard
You may also stack
NOTE: When transporting in a rack,
When using an equipment rack, do not mount units directly on top of each other. Allow 2 U between units for convection cooling. The side walls of the rack should be a minimum of two inches (5.1 cm) away from the amplifier sides, and the back of the rack should be a minimum of four inches (10.2 cm) from the amplifier back panel.
2.2 How to Attach Rack Ears
1. Locate the two rack ears and two
2.See Figure 2.2. Remove the two screws from each side of the chassis near the front.
3.Place a rack ear flush with the right front of the
chassis.
4.Insert a screw that you removed into the bottom hole of the rack ear and chassis. Screw it in.
5.Insert a screw that you removed into the center
hole of the rack ear and chassis. Screw it in.
6.Insert one of the supplied screws into the top hole of the rack ear and chassis. Screw it in.
7. Repeat steps | Figure 2.2 How to Connect Rack Ears |
|
3.5 In.
8.9 cm
17.3 In.
43.8 cm
12.2 In.
31.0 cm
4.1In.
10.5cm
13.9In.
35.2cm
Figure 2.1 Dimensions
page 8 | Operation Manual |