Crown Audio CTs 2-Channel specifications CTs Series 2-channel, Features, Specifications

Models: CTs 2-Channel

1 2
Download 2 pages 28.82 Kb
Page 1
Image 1
CTs Series 2-channel

CTs Series 2-channel

uilding on the foundation of the Crown® BCom-Tech®Series, the CTs Series offers new

flexibility and value for installed sound appli- cations. The Com-Tech Series was the first to offer independent selection of high- and low-impedance operation for a specific channel, and CTs Series amplifiers continue that tradition, with power levels and features carefully chosen to perfectly integrate into fixed install design requirements. For added flexibility, the CTs Series includes both dual-channel and multi-channel models.

All models in the CTs Series feature Crown’s new Switching Power Supply for lighter weight, and all models are also compatible with Harman Pro System Architect as well as the IQ System®. Two-channel models accept PIP2™ modules, and also feature selectable high-pass filters and input sensitivity for each channel.

In a profession where unplanned service calls quickly wipe out profits, the CTs Series amplifiers are designed to be the most reliable amplifiers you can install.

For more details about the Crown CTs Series, contact Crown Customer Service at 800-342-6939 or 574-294-8200. Also, visit the Crown Audio website at www.crownaudio.com.

C T s S E R I E S

Features

• Switching Power Supply for reduced weight

• Comprehensive array of indicators including Power,

• High power-density, with all two-channel models in

Data and Bridge, along with Ready, Signal, Clip,

Thermal and Fault for each channel, provide accurate

a 2U chassis

diagnostics

• Direct constant-voltage (70V/100V/140V/200V) or

• Blue Power Indicator flashes if the AC mains is

low-impedance (2/4/8 ohm) operation

under/over voltage

• Input sensitivity independently selectable for each

• Advanced protection circuitry guards against: shorted

channel

outputs, DC, mismatched loads, general overheating,

• TLC protection circuitry protects the amplifier from

under/over voltage, high-frequency overloads and

long-term excessive heat by subtly and dynamically

internal faults

reducing the gain only when necessary

• JTs circuitry (CTs 600/1200) quickly protects output

• PIP2 (Programmable Input Processor) connector

transistors from unsafe operating conditions without

accepts accessory modules that tailor the amplifier

shutting the channel down

to suit specific applications

• Legendary Crown AB+B (Multi-Mode®) output

 

• Removable terminal block input connectors, with “Y”

topology in the CTs 600/1200 and Class I (BCA®)

Input Switch in the standard PIP2-BBY module

output topology in the CTs 2000/3000 offer the best

• Switchable high-pass filter for each channel provides

in amplifier reliability

low-frequency roll off to eliminate step down trans-

• Continuously variable fans optimize cooling efficiency

former saturation when used in distributed systems

• Three Year, No-Fault, Fully Transferable

 

 

Warranty completely protects your investment and

 

guarantees its specifications

CTs 2000

20 Hz–20 kHz

Power

2-ohm Dual (per ch.)

1000W

4-ohm Dual (per ch.)

1000W

8-ohm Dual (per ch.)

1000W

16-ohm Dual (per ch.)

625W

70V Dual (per ch.)

1000W

100V

Dual (per ch.)

1000W

4-ohm Bridge

2000W

8-ohm Bridge

2000W

16-ohm Bridge

2000W

140V

Bridge

2000W

200V

Bridge

2000W

20 Hz–20 kHz Power refers to maximum average power in watts from 20 Hz to 20 kHz with 0.35% THD.

CTs 3000

20 Hz–20 kHz

Power

2-ohm Dual (per ch.)

1500W

4-ohm Dual (per ch.)

1500W

8-ohm Dual (per ch.)

1250W

16-ohm Dual (per ch.)

625W

70V Dual (per ch.)

1500W

100V

Dual (per ch.)

1500W

4-ohm Bridge

3000W

8-ohm Bridge

3000W

16-ohm Bridge

2500W

140V

Bridge

3000W

200V

Bridge

3000W

20 Hz–20 kHz Power refers to maximum average power in watts from 20 Hz to 20 kHz with 0.35% THD.

Specifications

Minimum Guaranteed Power: See power charts at left.

Frequency Response (at 1 watt, 20 Hz - 20 kHz): ±0.25 dB.

Signal to Noise Ratio below rated power (20 Hz to 20 kHz): 105 dB A-weighted.

Total Harmonic Distortion (THD) at full rated power, from 20 Hz to 20 kHz: CTs 600/1200: < 0.1%. CTs 2000/3000 < 0.35%.

Damping Factor: 10 Hz to 100 Hz: > 3000.

Crosstalk (below rated power, 20 Hz to 1 kHz): > 80 dB.

Common Mode Rejection (CMR) (20 Hz to 1 kHz): 50 dB.

DC Output Offset: < ±2 mV.

Input Impedance (nominal): 10 kilohms balanced, 5 kilohms unbalanced.

Maximum Input Level: +20 dBu before input com- pression, +32 dBu absolute maximum.

Load Impedance: (Note: Safe with all types of loads)

CTs 600/1200

Stereo: 2/4/8/16 ohms, 70V, 100V

Bridge Mono: 4/8/16 ohms, 140V.

CTs 2000/3000

Stereo: 2/4/8/16 ohms, 70V, 100V

Bridge Mono: 4/8/16 ohms, 140V, 200V.

Page 1
Image 1
Crown Audio CTs 2-Channel specifications CTs Series 2-channel, Features, Specifications, C T s S E R I E S