2-7. RELAY CONTACT CLOSURE OUTPUTS.
Relays
Type: Dry Contact Closure
Rating: 15A maximum current per zone
2-8. FUSE.
F1 Type GMC 2A, 250V
F2 Bussman-type GMT 4A
2-9. PHYSICAL.
A. AR2000-M
Weight 16 lb 8 oz. (7.5 kg.)
Dimensions (HWD) 3.5" x 17 3/8" x 14.25"
89mm x 442mm x 362mm
Case Material 14GA Aluminum
B. AR2000-P
Weight 3 lb, 15 oz. (1.8 kg)
Dimensions (HWD) 1.75" x 17 3/8” x 10.125"
44.5mm x 442mm x 257mm
Case Material 14GA Aluminum
C. AR2000-P
Weight 3 lb, 15 oz. (1.8 kg)
Dimensions (HWD) 1.75" x 17 3/8” x 10.125"
44.5mm x 442mm x 257mm
Case Material 14GA Aluminum
2-10. AGENCY APPROVALS.
A. UL AND cUL Certifications.
UL 813, (AZJX) Commercial Audio and Radio Equipment, Systems and accessories
C22.2 No. 1-98, (AZJX7) Audio, Video, and Similar Electronic Equipment
B. CSA Certification-Pending
C22.2 No. 1-98, Audio, Video, and Similar Electronic Equipment
C. FCC.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.