Amplifier Specifications

(For more detail, refer to the CTs multichannel amplifier datasheet)

Minimum Guaranteed Power: See power

charts at right.

Frequency Response (at 1 watt, 20 Hz - 20 kHz): ±0.5 dB.

Phase Response (at 1 watt, 10 Hz - 20 kHz):

±35°.

Signal to Noise Ratio below rated power (20 Hz to 20 kHz): 100 dB unweighted.

Total Harmonic Distortion (THD) at 1 watt, from 20 Hz to 20 kHz: < 0.05%.

Intermodulation Distortion (IMD) 60 Hz and 7 kHz at 4:1, from 163 milliwatts to full band- width power: < 0.05% (typical).

Damping Factor: 10 Hz to 400 Hz: >180.

Crosstalk (below rated power, 20 Hz to 1 kHz): > 80 dB.

Common Mode Rejection (CMR) (20 Hz to 1 kHz): > 50 dB.

DC Output Offset (shorted input): < ±5 mV.

Input Impedance (nominal): 20 kilohms bal- anced, 10 kilohms unbalanced.

Maximum Input Level (before input compres- sion): + 20 dBu.

Load Impedance: (Note: Safe with all types of loads)

Stereo: 4/8 and 25 ohms (70V)

Bridge Mono: 8/16 and 50 ohms (100V)

Voltage Gain (at maximum level setting), 1.4V sensitivity,

4/8 Ohm Operation: 20:1 (26 dB);

70V Operation: 50:1 (34 dB)

100V Operation: 71.4:1 (37 dB)

Required AC Mains: 120V 60 Hz, 220/230/240V/50 Hz.

Power Draw at Idle (120VAC mains, all chan- nels in 4/8 ohm mode): 58W.

Power Draw at Idle (120VAC mains, all chan- nels in 70V mode): 77W.

Cooling: Continuously variable speed forced air, front-to-back airflow.

Dimensions (Width, Height, Depth):

CTs 4200USP/CN: 19 in. (48.3 cm) W x 3.5 in. (8.9 cm) H x 16.25 in. (41.3 cm) D.

CTs 8200USP/CN: 19 in. (48.3 cm) W x 5.25 in. (13.3 cm) H x 16.25 in. (41.3 cm) D.

Front Panel Indicators

Bridge mode

Ready

Signal

Clip

Thermal

Fault

Data

Power

Front Panel Controls

Power switch

Back Panel Controls

Channel level controls

Dual/bridge-mono mode switch

Back Panel Connectors

Output Connectors: One four-pole terminal strip for every two channels with touch-proof cover. Accepts up to 10 AWG terminal forks.

Input Connectors: Removable Phoenix-style barrier connectors for balanced input. Also can be used as a CobraNet input or a backup for CobraNet.

Protection Systems

Thermal Level Control

Fault Isolation Topology

Fault

Highpass filter

AC under/over voltage protection

Power fuse

Inrush limiting

Variable speed fan

CTs 4200USP/CN

CTs 8200USP/CN

CTs 4200USP/CN

Dual

Maximum Average Power

in watts with 0.1% THD.

4 Channels Driven

1 kHz

20

Hz–20 kHz

4-ohm (per ch.)

260W

 

215W

8-ohm (per ch.)

180W

 

190W

70V (per ch.)

220W

 

220W*

1 Channel Driven

1 kHz

20

Hz–20 kHz

4-ohm (per ch.)

270W

 

225W

8-ohm (per ch.)

220W

 

210W

70V (per ch.)

250W

 

245W*

Bridge-Mono

 

 

 

2 Channel-Pairs Driven

1 kHz

20

Hz–20 kHz

8-ohm (per ch. pair)

520W

 

430W

16-ohm (per ch. pair)

400W

 

380W

100V (per ch. pair)

220W

 

220W*

1 Channel-Pair Driven

1 kHz

20

Hz–20 kHz

8-ohm (per ch. pair)

560W

 

450W

16-ohm (per ch. pair)

440W

 

420W

100V (per ch. pair)

250W

 

245W*

*Constant Voltage full bandwidth power ratings support 100Hz - 20kHz due to automatic High-Pass Filters.

CTs 8200USP/CN

Dual

Maximum Average Power

in watts with 0.1% THD.

8 Channels Driven

1 kHz

20

Hz–20 kHz

4-ohm (per ch.)

200W

 

175W

8-ohm (per ch.)

160W

 

155W

70V (per ch.)

200W

 

185W*

1 Channel Driven

1 kHz

20

Hz–20 kHz

4-ohm (per ch.)

270W

 

230W

8-ohm (per ch.)

220W

 

220W

70V (per ch.)

250W

 

230W*

Bridge-Mono

 

 

 

4 Channel-Pairs Driven

1 kHz

20

Hz–20 kHz

8-ohm (per ch. pair)

400W

 

350W

16-ohm (per ch. pair)

320W

 

310W

100V (per ch. pair)

200W

 

185W*

1 Channel-Pair Driven

1 kHz

20

Hz–20 kHz

8-ohm (per ch. pair)

540W

 

460W

16-ohm (per ch. pair)

440W

 

440W

100V (per ch. pair)

250W

 

230W*

*Constant Voltage full bandwidth power ratings support 100Hz - 20kHz due to automatic High-Pass Filters.

Crown’s Three-Year, No-Fault, Fully Transferable Warranty

Crown offers a Three-Year, No-Fault, Fully Transferable Warranty for every new Crown amplifier— an unsurpassed industry standard. With this unprecedented No-Fault protection, your new Crown amplifier is warranted to meet or exceed original specifications for the first three years of owner- ship. During this time, if your unit fails, or does not perform to original specifications, it will be repaired or replaced at our expense. About the only things not covered by this warranty are those losses normally covered by insurance and those cuased by intentional abuse. And the coverage is transferable, should you sell your amplifier.

See your authorized Crown dealer for full warranty disclosure and details. For customers outside of the USA, please contact your authorized Crown distributor for warranty information or call 574-294-8200.

Crown International 1718 W. Mishawka Rd. Elkhart, IN 46517-9439 TEL: 574-294-8200 FAX: 574-294-8FAX www.crownaudio.com

Specifications subject to change without prior notice. Latest information available at www.crownaudio.com and iqaudiosystems.com.

Crown and Crown Audio are registered trademarks; PIP is a trademark of Crown International. HiQnet and System Archi- tect are trademarks of Harman International Industries, Inc.

Other trademarks are the property of their respective owners. Printed in U.S.A.

© 2008 Crown Audio®, Inc.

2/08

139279-2

 

 

 

 

Page 2
Image 2
Crown Audio CTs 4200 USP/CN CTs 4200USP/CN, CTs 8200USP/CN, Crown’s Three-Year, No-Fault, Fully Transferable Warranty