C T s S E R I E S
CTs 4200USP/CN
CTs 8200USP/CN
Input module on back panel
he Crown® CTs 4200USP/CN and CTs T8200USP/CN power amplifiers have an
Input Module Features (For amplifier features, see the CTs multichannel amplifier datasheet.)
integrated 3rd generation,
The CTs 4200USP/CN and CTs 8200USP/CN amplifiers connect to a HiQnet™ audio con- trol/monitor network using standard 100 Mbps Ethernet hardware (switches, Network Interface Cards, and cables). CobraNet™ audio is available over the same 100 Mbps Ethernet network, providing a
•100 Mbps Ethernet
•Analog audio inputs allow CobraNet network audio input, CobraNet audio backup, or a hard- wire emergency override of CobraNet audio
•24 bit digital to analog conversion with 32 bit, floating point DSP processing
•Up to 18 assignable filters per channel with 9 different filter types including
•Over 2 seconds of delay available per channel
•Input compressors and output limiters for each channel
•Dual, uncorrelated noise generators for noise masking
•Sine generator
•Load supervision
•Full error reporting
•Firmware upgrades via the network
•10 user selectable presets
•Reliable FLASH memory backup of all parameters
•Three Year,
The input module’s SHARC DSP processors give the user an enormous amount of digital signal processing. Audio routing, faders, meters, polarity & mute, input compressors, filters, delays, multimode output limiters, error reporting, and load monitoring are all avail- able. A built in noise generator and
These amplifiers require Harman Pro System Architect software available from www.crown- audio/forums.
For more details about the Crown
CTs 4200USP/CN and CTs 8200USP/CN, contact the Crown Technical Support Group at 800-
Input Module Specifications
Connectors:
AUX Connector
Configurable for AUX input, AUX output and Listen Bus. Listen Bus is also supported through CobraNet.
Network Connector
The dual RJ45 CobraNet connectors allow a Primary & Secondary connection to the 100Mb Ethernet network. Should the Primary connec- tion lose link activity with the network, the input module will automatically switch to the Second- ary connection to ensure uninterrupted audio and control. The indicators on the RJ45 con- nectors display network information concerning the Ethernet and CobraNet connections.
Indicators:
Preset Indicator
Signals the number of the current preset, if active, by flashing a series of flashes equal to the current preset number.
IQ Data Indicator
Flashes when the module receives a valid command that is addressed to the CTs 4200 USP/CN and CTs 8200USP/CN.
Switches:
Reset/Preset Switch
Used to change presets, restore settings to factory default or restore all the presets to the factory defaults. During operation of the
switch, the Data indicator flashes as an aid to the user. Accessible with a straightened paper clip through the rear panel, the switch selects the next user preset if pressed for less than
2 seconds, resets the module to preset “0” if pressed for more than 2 seconds.
General:
Memory Backup:
Communications: 100Mb Fast Ethernet con- forming to IEEE 802.3.
Overall Audio Performance:
DSP Processing: Two processors, 32 bit, Floating Point, 724 µs latency.
D/A and A/D Conversion: 24 bit.
Latency:
DSP processing: 1 ms or 1000 µs.
Amplifier: 100 µs.
Total: 1.6 ms or 1000 µs.
Dynamic Range: 103 dB typical (A- weighted,
Distortion: < 0.1% THD+N,
Frequency Response: ± 0.5 dB, 20Hz– 20kHz.
Input/Output Monitor Accuracy: Typically
±1dB.
Maximum Input Level: + 20 dBu.