D Series Power Amplifiers

6 Specifications

D-45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Aver-

 

 

Single-Cycle Tone Burst

 

 

 

 

40 mS Tone Burst

 

 

EIA Watts at

 

 

Configuration and Load

 

FTC Continuous

 

age Power at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watts at < 0.05% THD

 

 

 

Watts at < 0.05% THD

 

 

1% THD

 

 

 

Average Power at 0.1% THD

 

0.1% THD

 

 

 

 

 

 

 

 

 

(ohms)

 

 

 

 

 

(See note 1)

 

(See note 2)

 

 

 

 

(See note 3)

 

 

 

 

 

(See note 4)

 

 

(See note 5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20Hz-20kHz

 

1 kHz

 

1 kHz

 

20 Hz

 

 

50 Hz

 

1 kHz

 

20 Hz

 

 

50 Hz

 

1 kHz

 

1 kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dual

 

 

 

 

 

 

 

 

4

 

 

 

 

35

 

40

 

50

 

75

55

 

60

 

60

35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

20

25

25

 

25

 

30

 

35

40

 

40

 

40

25

 

 

(both channels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

driven)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

20

20

20

 

20

 

20

 

20

20

 

20

 

20

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bridge-Mono

 

 

 

 

 

 

 

 

8

 

 

 

 

70

 

85

 

105

 

145

85

 

85

 

85

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(balanced output)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

40

50

50

 

50

 

60

 

70

50

 

50

 

55

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6.1

D-45 Power Matrix

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D-75A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Aver-

 

 

Single-Cycle Tone Burst

 

 

 

 

 

40 mS Tone Burst

 

 

EIA Watts at

 

 

Configuration and Load

 

FTC Continuous

 

age Power at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Watts at < 0.05% THD

 

 

 

Watts at < 0.05% THD

 

 

1% THD

 

 

 

Average Power at 0.1% THD

 

0.1% THD

 

 

 

 

 

 

 

 

 

(ohms)

 

 

 

 

 

(See note 1)

 

(See note 2)

 

 

 

 

(See note 3)

 

 

 

 

 

(See note 4)

 

 

(See note 5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20Hz-20kHz

 

1 kHz

 

1 kHz

 

20 Hz

 

 

50 Hz

 

1 kHz

 

20 Hz

 

 

50 Hz

 

1 kHz

 

1 kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dual

 

 

 

 

 

 

 

4

 

45

 

50

 

55

 

65

 

 

85

 

120

 

65

 

 

70

 

70

 

55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

35

 

40

 

40

 

45

 

 

50

 

60

 

45

 

 

45

 

45

 

40

 

 

(both channels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

driven)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

25

 

25

 

25

 

25

 

 

30

 

30

 

25

 

 

25

 

25

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bridge-Mono

 

 

 

 

 

 

8

 

95

 

105

 

110

 

140

 

 

165

 

235

 

140

 

 

140

 

140

 

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(balanced output)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

70

 

75

 

80

 

90

 

 

100

 

130

 

90

 

 

90

 

95

 

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6.2 D-75A Power Matrix

Notes:

All power matrix specifications are based on a 0.1% regulated 120 VAC, 60 Hz power mains and an ambient room temperature of 70° F (21° C).

1.Continuous power in the context of Federal Trade Commission testing is understood to be a minimum of five minutes of operation. Harmonic distortion is measured at the RMS sum total as a percentage of the fundamental output voltage. This applies for all wattages greater than 0.25 watts.

2.A 1 kHz sine wave is presented to the amplifier and the output monitored for nonlinear distortion. The level is increased until the THD reaches 0.1%. At this level the average power per channel is reported.

3.A single cycle sine wave is presented to the amplifier and monitored for nonlinear distortion. The average power during the burst is reported. Loudspeakers must be able to withstand this level if they are to be safely used with this amplifier.

4.A 40 millisecond burst or a two cycle sine wave (whichever is of greater duration) is used and the power computed as the average power during the burst. The duty cycle of this test is 10 percent. This power level is a measure of how loud an amplifier is as perceived by the human ear.

5.EIA standard RS-490 (both channels driven).

page 16

Operation Manual

Page 16
Image 16
Crown Audio D-75A, D-45 KHz 20 Hz 50 Hz Dual, Bridge-Mono 105 145, Hz KHz 20 Hz Dual 120, 110 140 165 235 105, 100 130

D-45, D-75A specifications

Crown Audio has earned its reputation as a leader in professional audio solutions, with a commitment to delivering high-quality amplifier technology that meets the demands of audio professionals across various applications. Two notable models in their lineup are the Crown D-75A and D-45, both of which embody unique features that are tailored for versatility and superior performance.

The Crown D-75A is a high-performance power amplifier designed for applications where exceptional sound quality is essential. With an output power of 75 watts per channel into 8 ohms, this amplifier is capable of driving a wide range of loudspeakers, making it an excellent choice for installations in commercial venues or high-end residential systems. One of its standout features is the ability to operate in both stereo and bridged mono modes, allowing for flexible configuration options. The D-75A also incorporates Crown’s patented Class I technology, which enables it to maintain high efficiency while minimizing distortion and heat generation.

On the other hand, the Crown D-45 offers a slightly lower output power, rated at 45 watts per channel into 8 ohms. Despite its smaller size, the D-45 packs a punch with its robust performance and advanced technologies. This amplifier is well-suited for smaller venues or as a part of an audio system where space is a concern. Just like the D-75A, the D-45 features the ability to run in stereo or bridged mono modes, providing users with flexibility in setup.

Both amplifiers incorporate user-friendly front-panel controls, including level adjustments and power indicators, allowing for easy operation and monitoring. Furthermore, they are engineered with short-circuit and thermal overload protection, ensuring longevity and reliability in demanding environments.

In terms of connectivity, the D-75A and D-45 come equipped with professional-grade XLR and RCA input options, facilitating seamless integration into various audio systems. Their durable construction is designed to withstand the rigors of professional use, while also being aesthetically pleasing for any installation.

In conclusion, the Crown Audio D-75A and D-45 amplify the brand’s commitment to quality and innovation, providing professionals with dependable solutions that do not compromise on sound fidelity. Whether for a small venue or a large installation, these amplifiers deliver the performance and features audio engineers seek, making them an excellent choice in the competitive world of sound reinforcement.