Crown Audio K Series operation manual Troubleshooting, CONDITION No power to the amplifier, page

Models: K Series

1 20
Download 20 pages 63.11 Kb
Page 14
Image 14
6 Troubleshooting

K Series Power Amplifiers

6 Troubleshooting

CONDITION: No power to the amplifier.

POSSIBLE REASON:

The amplifier's Power switch is off.

The amplifier is not plugged into the power receptacle.

The amplifier's low-voltage power supply fuse has blown. Return amp to Crown or an authorized Crown Service Center for servicing.

CONDITION: Distorted sound.

POSSIBLE REASON:

Input signal level is too high. Turn down your amplifier level controls. NOTE: Your amplifier should never be operated at a level which causes the Clip LED to flash constantly.

Load is wired incorrectly or Bridge Mono Switch is set incorrectly. Check both.

Note: If sound is distorted but clip LED is not flashing, check mixer levels and gain staging, mixer clip lights, and pads built into micro- phones.

CONDITION: Input signal but no sound.

POSSIBLE REASON:

The amplifier has just been turned on and is still in the 4-second turn-on delay.

Speakers not connected.

CONDITION: No input signal.

POSSIBLE REASON:

Input signal level is very low.

Level controls are turned down.

Input cables are not connected.

CONDITION: TLC indicator glows brightly.

POSSIBLE REASON:

The amplifier is protecting itself with the thermal level control system. Turn on a fan or turn down the level controls.

page 14

Operation Manual

Page 14
Image 14
Crown Audio K Series operation manual Troubleshooting, CONDITION No power to the amplifier, CONDITION Distorted sound, page