E:Special Requirements For Side-Wall Vented Appliances In The Commonwealth of Massachusetts

IMPORTANT

The Commonwealth of Massachusetts requires compliance with regulation 248 CMR 4.00 and 5.00 for installation of side-wall vented gas appliances as follows:

1.For direct-vent appliances, mechanical-vent heating appliances or domestic hot water equipment, where the bottom of the vent terminal and the air intake is installed below four feet above grade the following requirements must be satisfied:

a.If there is not already one present, on each floor level where there are bedroom(s), a carbon monoxide detector and alarm shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply with NFPA 720 (2005 Edition).

b.A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall:

i.Be powered by the same electrical circuit as the appliance or equipment such that only one service switch services both the appliance and the carbon monoxide detector;

ii.Have battery back-up power;

iii.Meet ANSI/UL 2034 Standards and comply with NFPA 720 (2005 Edition); and

iv.Have been approved and listed by a Nationally Recognized Testing Laboratory as recognized under 527 CMR.

c.A product-approved vent terminal must be used, and if applicable, a product-approved air intake must be used. Installation shall be in strict compliance with the manufacturer’s instructions. A copy of the installation instructions shall remain with the appliance or equipment at the completion of the installation.

d.A metal or plastic identification plate shall be mounted at the exterior of the building, four feet directly above the location of the vent terminal. The plate shall be of sufficient size to be easily read from a distance of eight feet away, and read “Gas Vent Directly Below”.

2.For direct-vent appliances, mechanical-vent heating appliances or domestic hot water equipment, where the bottom of the vent terminal and the air intake is installed above four feet above grade the following requirements must be satisfied:

a.If there is not already one present, on each floor level where there are bedroom(s), a carbon monoxide detector and alarm shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply with NFPA 720 (2005 Edition).

b.A carbon monoxide detector shall :

i.Be located in the room that houses the appliance or equipment

ii.Be either hard-wired or battery powered or both; and

iii.Comply with NFPA 720 (2005 Edition)

c.A product-approved vent terminal must be used, and if applicable, a product-approved air intake must be used. Installation shall be in strict compliance with the manufacturer’s instructions. A copy of the installation instructions shall remain with the appliance or equipment at the completion of the installation.

23

Page 25
Image 25
Crown Boiler BWC150, BWC225 manual

BWC225, BWC150 specifications

The Crown Boiler BWC series, specifically the BWC150 and BWC225 models, are renowned for their performance and efficiency in residential and commercial heating applications. These boilers are designed to provide optimal heating while ensuring reliability and user-friendliness.

A standout feature of the BWC series is its high efficiency. Both the BWC150 and BWC225 are equipped with cutting-edge technology that maximizes energy use, effectively reducing operating costs. Their design utilizes a modulating burner, which adjusts the heat output based on demand. This modulation not only enhances comfort levels by maintaining a steady temperature but also conserves energy, making these models eco-friendly options.

The BWC series incorporates a durable cast-iron heat exchanger, known for its longevity and excellent heat transfer capabilities. This feature ensures that the boilers can withstand the rigors of daily operation while delivering consistent performance over time. Furthermore, the built-in control systems allow for precise monitoring and adjustment, ensuring that users have access to real-time information about their heating systems.

Another notable characteristic is the compact design of these boilers. The BWC150 and BWC225 fit seamlessly into various spaces, making them ideal for both new installations and replacements in existing systems. The straightforward installation process is a significant advantage for contractors and homeowners alike, saving time and resources.

Moreover, safety is a priority in the design of the BWC series. Each model includes multiple safety features, including low water cut-off, high-temperature limit control, and pressure relief valves. These features not only protect the boiler itself but also ensure the safety of the home or building in which it operates.

The Crown Boiler BWC series also boasts compatibility with various heating systems, including hot water baseboard, radiators, and in-floor heating, providing versatility to meet different heating needs. Its user-friendly interface and control options make it accessible to users, whether they are tech-savvy or not.

In conclusion, the Crown Boiler BWC150 and BWC225 models offer a combination of energy efficiency, robust construction, and advanced technology. With their modulating burners, durable heat exchangers, compact design, and safety features, these boilers are an excellent choice for anyone looking to invest in a reliable heating solution.