Check Oil Level

NOTE: Be sure to check the engine on a level surface with the engine stopped.

1.Remove the oil filler cap and wipe the dipstick clean. See Fig. 9-2.

Oil Fill Cap/

Dipstick

Upper Level

Figure 9-2

2.Insert the dipstick into the oil filler neck, but do not screw it in.

3.If the level is low, slowly add oil to the upper limit on the dipstick. See Fig. 9-2 inset.

4.Tighten dipstick firmly before starting engine.

NOTE: Do not overfill. Overfilling with oil may cause smoking, hard starting, spark plug fouling, or oil saturation of air cleaner.

Fuel Recommendations

Use automotive gasoline (unleaded or low leaded to minimize combustion chamber deposits) with a minimum of 87 octane. Gasoline with up to 10% ethanol or 15% MTBE (Methyl Tertiary Butyl Ether) can be used. Never use an oil/gasoline mixture, dirty gasoline, or gasoline over 30 days old. Avoid getting dirt, dust, or water in the fuel tank. DO NOT use E85 gasoline.

WARNING: Gasoline is extremely flammable and is explosive under certain conditions. Refuel in a well- ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored. Avoid repeated or prolonged contact with skin or breathing of vapor.

WARNING: Do not overfill the fuel tank (there should be no fuel in the filler neck). After refueling, make sure the tank cap is closed properly and securely. Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite. If any fuel is spilled, make sure the area is dry before starting the engine.

Check Fuel Level

1.Clean around fuel fill before removing cap to fuel.

2.Fill tank to approximately 1-inch below lowest portion of neck to allow for fuel expansion. Be careful not to overfill. NOTE: Before refueling, allow engine to cool 2 minutes.

Starting The Engine

WARNING: Always keep hands and feet clear of equipment moving parts. Do not use a pressurized starting fluid. Vapors are flammable.

1.Push primer 3 times. Wait about two seconds between each push. See Fig. 9-3. In temperature below 50°F, prime

5 times. After the engine is warmed up, one prime may be needed for all temperatures.

2

3 1

3

Figure 9-3

2.Standing behind the mower, squeeze and hold the blade control against upper handle.

3.Recoil Start: Pull the recoil starter lightly until resistance is felt, then pull rapidly to overcome compression, prevent kickback, and start the engine. Repeat if necessary. See Fig.

9-3.

NOTE: Do not allow the recoil starter to snap back against the rope guide.

Electric Start: Turn ignition key to the right to start the engine. Release the key after the engine starts. See Fig. 9-3.

If engine does not start, it may be necessary to re-prime the engine.

Stopping The Engine

1.Release the blade control.

Section 9 — Operation

 

23