NOTE: Fuses and Wires

Regulations may require that the Model 833 be

!

fused. If installing a fuse, use a 10A fuse wired with

1.5mm or equivalent wire. The voltage drop across the fuse, its holder, and connectors must be less than 1% of the nominal system voltage.

Discharge Adjustments

Table 3 lists the voltages per cell under load that correspond to an empty indication on the gauge (lockout point).

Table 3. Discharge Adjustment Settings

Setting

Volt/Cell at Empty

K1.57

L1.63

M1.68

N1.73 (factory setting)

O1.78

P1.82

Q1.84

R1.86

S1.89

T1.91

U1.93

11