User’s Manual for CyberShield

CS24C12V-E

CyberShield UPSs are designed to provide a local power solution for cable telephony, wireless local loop (WLL), and fiber to the home (FTTH) broadband equipment.

IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)

This manual contains important instructions regarding the installation and operation of this device. Read this manual thoroughly before attempting to unpack , install or operate this device

CAUTION! The battery can energize hazardous live parts inside even when the AC input power is disconnected.

CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area, free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range).

CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service the battery. No user serviceable parts inside, except for the battery.

CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component.

ENCLOSURE INSTALLATION

Carefully follow these instructions during installation of this device:

1.) Carry out the installation in a safe area that is free of excessive dust and has adequate airflow.

2.) Screws must be appropriate for total weight of the UPS and the mounting surface material.

3.) Do not operate the UPS where the temperature and humidity are outside the specified limits. (Refer to specifications in this manual.)

OPERATION

Connect: Equipment and Power

Step1. Plug the UPS power cord into the utility power cord inlet

Step2. Plug the UPS power cord into the wall outlet.

The UPS battery charges when it is connected to utility power. The battery charges fully during the first 24 hours of normal operation. Do not expect full battery run capability during this initial charge period.

Step 1:

Step 2:

Step 3:

 

a. Remove the case screw.

a. Unstrap strap from battery.

a. Use the

enclosed installation template to

b. Open the battery cover.

b. Slide battery off of the

mark an installation location for the unit.

 

shelf.

b. Mount the unit on the wall with 3 mounting

 

c. Disconnect battery cable

screws into the keyhole slots.

 

connector at the chassis end.

c. Tighten the screws to secure the units.

 

 

d. Connect the battery connector and replace

 

 

the battery back.

BATTERY REPLACEMENT

This battery is hot-swappable. As long as utility power is on , you may leave the UPS and connected equipment on while replacing a new battery.

COLD START

The cold start feature is for applying power to the UPS and connected equipment when the UPS is off and there is no utility power. Before using the cold start feature, please make sure the battery is charged. To enable the cold start feature, press the recessed cold start button with a small pointed object.

Once the battery is disconnected, the connected equipment is not protected from power outages.

Deliver spent batteries to a recycling facility or ship to the manufacturer in the replacement battery packing material.

WARNING INDICATOR

Indicator Color Condition

 

 

 

 

 

 

 

Green

UPS is on utility power.

 

AC

Yellow

UPS is on battery power.

 

 

 

 

 

 

 

 

 

 

Green

DC output power is provided by the battery or

 

 

 

 

 

 

 

OUTPUT

 

utility power.

 

 

 

 

 

 

 

Red

The battery is not connected or the battery

BATTERY

 

needs to be replaced.

 

 

Front Panel

Step 1:

a. Remove the case screw. b. Open the battery cover.

Step 2:

a. Loosen the battery strap.

b. Disconnect battery cable connector to remove battery.

c. Replace with new battery and re-connect the battery connector.

Step 3:

a. Tighten the battery strip b. Close the battery cover and

lock the case screw.

CS24C12V2-E

Page 1
Image 1
CyberPower Systems CS24C12V-E user manual Enclosure Installation, Operation, Battery Replacement, Cold Start