Errata Document

CY8C22x13

 

 

 

 

TRIGGER CONDITION(S)

The asynchronous Rx/Tx clock source IMO frequency tolerance may deviate beyond the data sheet limit of ±2.5% when operated beyond the temperature range of 0 to +70°C.

SCOPE OF IMPACT

This problem may affect UART, IrDA, and FSK implementations.

WORKAROUND

Implement a quartz crystal stabilized clock source on at least one end of the asynchronous digital communications interface.

FIX STATUS

The cause of this problem and its solution has been identified. Silicon fix is planned to correct the deficiency in silicon.

References

[1] Document # 38-12009, CY8C22113 and CY8C22213 PSoC® Mixed-Signal Array Final Data Sheet

September 11, 2008

Document No. 001-48788 Rev. **

2

[+] Feedback

Page 2
Image 2
Cypress CY8C22x13 manual References, Trigger Conditions, Scope of Impact, Workaround, FIX Status