5
pl a n n i n G t h e lo c a t i o n
Carefullycheckthelocationwherethehoodis tobe•
installed.Thehoodshouldbeplacedforconvenient
access.Makecertainthatelectricalpowercanbe
providedintheselectedlocation.
Installtherangehoodandcookingappliance(s)so that•
theycanberemovedifserviceisrequired.
Plantheinstallationsothatallminimumdimensions•
aremetorexceeded(seepage3).Dimensions shown
provideminimumclearances,unlessotherwisenoted.

Preparing the Mounting Bracket Location

Themountingbracketmustbeattacheddirectlyto the•
studsintheceiling,ortoareinforced mountingblock
securedtothestuds.Seebelowformounting bracket
holedimensions.
Attachthemountingbracketdirectlyabovethecenter•
ofthecooktop.
Attachthemountingbrackettothemountingsurfaces•
with#12screws(notsupplied).Thescrewsmust beof
sufficientlengthtopenetrateintothewoodmounting
surfacesatleast11/2”(3.8cm).
Themountingsurfacemustbelevel.•
Allowclearanceinthecenterofthemounting bracket•
fortheexhaustducttopassthroughthe ceiling
(8-inchesindiameter).
el e c t r i c a l po w e r Su p p ly

Electrical Specifications

Itistheowner’sresponsibilitytoensure thattheelectrical
connectionofthisapplianceisperformedbya qualified
electrician.Theelectricalinstallation,includingminimum
supplywiresizeandgrounding,mustbein accordancewith
theNationalElectriccodeANSI/NFPA*(orlatestrevision)
andlocalcodesandordinances.
Connectthehoodtoa120Vac,60Hzdedicated,
grounded,circuitprotectedbya15Ampcircuitbreakeror
timedelayfuse.
*Acopyofthisstandardmaybeobtainedfrom:
NationalFireProtectionAssociation
1BatterymarchPark
Quincy,Massachusetts02269-9101

WARNING

Theelectricalservicetotherangehoodshould be•
installedonlybyalicensedelectrician.
Observeallgoverningcodesandordinancesduring•
planningandinstallation.Contactyourlocalbuilding
departmentforfurtherinformation.
DO NOT• usethemountinganchorsprovidedwiththe
unit.Theyarepartofastandardmounting hardware
packageprovidedwithmanyDacorhoods,butnot
suitableforusewiththismodel.
Therangehoodisheavy.Topreventpersonalinjury•
andpropertydamagecausedbythehoodcoming
loosefromtheceiling,mountthehoodmounting
bracketonlyasspecifiedbelow.
pr e p a r i n g f o r in s T a l l a T i o n
129/16”
(31.9cm)
61/8”
(15.6cm)
11”
(27.9cm)