Installation Instructions

Knob Installation

Control Panel -

1. Attach the SimmerSear burner knobs A as shown

DRT304S

below. The SimmerSear knobs have a wider space

 

between the large flame icon and the simmer icon than

 

the standard burner knobs. Align the “D-shaped” open-

B

ing on the back of each knob with the end of the valve

shaft. Carefully push each knob on until it stops.

A

2. Attach the remaining knobs which operate the standard

B

burners B .

B

A

Control Panel -

 

DRT366S

SimmerSear Burner Knob Layout

B

 

A

B

B

 

B

Standard Burner Knob Layout

A

Gas Line Connection

B

 

warning

Verify that the gas supply meets specifications before connection. See page 3.

The maximum gas supply pressure to the regulator must never exceed ½ pounds per square inch (psi) or 3.5 kPa.

Do not install or use the cooktop without the included gas regulator installed.

Ensure that the arrow on the regulator points in the direction of the gas flow, towards the cooktop.

Do not apply excessive pressure when tightening gas connections and fittings.

Do not use Teflon tape or plumber’s putty on flexible gas line connections.

Test the gas lines for leaks as instructed before use. Do not use a flame to check for leaks.

The gas supply pressure for testing the regulator set- ting shall be at least 1 inch water column (249Pa) above the specified manifold pressure. See page 3.

The cooktop and shut-off valve must be disconnected from the gas supply piping system during any pres- sure testing exceeding ½ p.s.i. (3.5 kPa).

The cooktop must be isolated from the gas supply piping system by closing the shut-off valve to the cooktop during any gas supply piping system pres- sure testing equal to or less than ½ p.s.i. (3.5 kPa).

For LP gas installations, the LP gas tank must have its own high-pressure regulator in addition to the pressure regulator supplied with the cooktop.

important

Within the Commonwealth of Massachusetts, this appliance must be installed by a licensed plumber or gas fitter.

1.Attach the gas pressure regulator (included with the cooktop) to the 3/4” (19 mm) male NPT gas inlet on the cooktop. The inlet is located on the bottom, at the right rear portion of the chassis. For tight installations, the regulator may be installed upstream from the pipe nipple, anywhere between the shut-off valve and the cooktop. For best performance, minimize gas pressure loss by attaching the regulator as close as possible to the cooktop gas inlet.

2.Complete connection of the gas supply to the cooktop by installing a minimum ½” flexible gas line (not includ- ed) between the pressure regulator and the shut-off valve.

3.Check for gas leaks:

Turn all cooktop control valves to the OFF position.

Turn on the gas supply valve and check all lines and connections for leaks using a soap and water solution or a gas leak detector.

Turn the gas supply valve off.

8