Dacor Cooktops 2/2, Clearances to Combustibles, PGM304-1, PGM365-1, 30”, 36”, 46”, Wide, Guide

Models: PGM365-1 PGM304-1

1 2
Download 2 pages 21.24 Kb
Page 2
Image 2
Cooktops 2/2

PGM304-1, PGM365-1

Revised 06/24/08

30”, 36”, 46”

Wide,

PLANNING

Preference™ Gas

Cooktops 2/2

GUIDE

 

 

 

A

All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.

13" Max.

18" Min.

(330 mm)

(457 mm)

 

30" Min.

(762 mm)

3 1/8" Min.

(79 mm)

 

1/4” (6 mm)

 

Mimimum clearance

 

to combustible

B

surfaces

Under Cabinet Clearances

(Front View)

 

“B”

Model

Minimum

PGM304-1

29” (737 mm)

PGM365-1

35 1/4” (895 mm)

 

 

Clearances to Combustibles

Model

“A”“A” Minimum Recommended

PGM304-1

30” (762 mm)

36” (914 mm)

PGM365-1

36” (914 mm)

42” (1067 mm)

 

 

 

 

Dedicated

Total

 

Approximate

 

Circuit

Connected

Gas Supply

Shipping

Model No.

Required

Load

Requirements

Weight

 

 

 

1/2” (13 mm)

 

PGM304-1

 

 

Regulator -

53 lbs.

120 Vac,

 

Natural Gas

 

 

 

 

60 Hz,

0.03 kW

Standard

 

 

15 Amp

(0.25 Amp)

3/4” (19 mm)

 

PGM365-1

(Breaker)

 

Regulator -

67 lbs.

 

 

Natural Gas

 

 

 

 

 

 

 

Standard

 

Clearances to Combustibles NOTES:

1.Factory installed propane (LP) special ordered.

2.Cooktop is supplied with a 40” (1016 mm) power cord, with a three-prong grounded plug.

3.Utilities connections are located on the bottm of the chassis at the right rear corner of the cooktop.

4.See the Combination Installation (CI) section if installing with a downdraft, wall oven, or warming oven.

Web: http://www.Dacor.com

Specifications are subject to change without notice.

4.8

Corporate Phone: 800-793-0093

See installation instructions for additional details.

Page 2
Image 2
Dacor Cooktops 2/2, Clearances to Combustibles, PGM304-1, PGM365-1, 30”, 36”, 46”, Wide, Planning, Preference Gas