PIN CONNECTOR

PIN CONNECTOR

Pin

Signal

 

 

1

Red

1

 

2

Green

 

 

 

3

Blue

 

 

4

GND

6

10

5

GND

6

GND - Red

 

 

7

GND - Green

 

15

8

GND - Blue

 

 

9

Reserved

Arrangement of 15-pin D-sub connector

10

GND - H.Sync

 

 

11

GND

 

 

12

Bi-directional Data (SDA)

 

 

13

Horizontal Sync

 

 

14

Vertical Sync (VCLK)

 

 

15

Data Clock (SCL)

 

 

CAUTIONS FOR ADJUSTMENT AND REPAIR

Degaussing is always required when adjusting purity or convergence.

The white balance adjustment has been done by a color analyzer in factory. The adjustment procedure, described in the service manual is made by a visual check.

Allow 20 minutes warm-up time for the display before checking or adjusting only electrical specification or function.

Reform the leadwire after any repair work.

Caution For Servicing

In case of servicing or replacing CRT, high voltage sometimes remains in the anode of the CRT. Completely discharge high voltage before servicing or replacing CRT to prevent a shock to the serviceman.