ALIGNMENT INSTRUCTIONS
1.MAIN TUNER AGC
1)Set a Pattern Generator with RF level 62 6 2 dBuV, 210.25 MHz.
2)Connect a OSCILLOSCOPE PROBE to P101 ( TUNER AGC INPUT ).
3)Adjust AGC UP/DOWN KEY the voltage drop about 1V DC over below it's maximum voltage.
2.SCREEN
1)Apply a COLOR BAR PATTERN SIGNAL.
2)Press the "SCREEN" KEY .
3)Connect a OSCILLOSCOPE PROBE to P901 ( CRT CATHODE R,G,B )
4)Adjust the screen volume on FBT such that the highest black level voltage 120V6 5Vdc . ∗ Another methode
1)Press "AV Key" in condition of AV no signal.
2)Press the "SCREEN" KEY .
3)Connect a OSCILLOSCOPE PROBE to P901 ( CRT CATHODE R,G,B )
4)Adjust the screen volume on FBT such that the highest black level voltage 140 V6 5Vdc .
3.WHITE BALANCE
1)Apply a COLOR BAR PATTERN SIGNAL.
2)Adjust the R,G,B UP/DOWN KEY of the other color which did not appear on the screen to obtain WHITE.
4.FOCUS
1)Apply a RETMA PATTERN SIGNAL.
2)Adjust the FOCUS VOLUME on FBT to obtain optimal resolution.
5.GEOMETRY
5.1 S-CORRECTION
1)Apply a CROSSHATCH PATTERN SIGNAL.
2)Adjust the
5.2 VERTICAL SLOPE
1)Apply a RETMA PATTERN SIGNAL.
2) Pressing the
3)Adjust the border line of blanked picture coincident with the center marks of the pattern using the
5.3 VERTICAL CENTER
1) Apply a RETMA PATTERN SIGNAL.
2) Adjust the center line of pattern coincident with the mechanical center marks of the CRT using the
5.4 VERTICAL SIZE
∗The
1) Apply a RETMA PATTERN SIGNAL.
2) Adjust the upperside of the pattern coincident with the mechanical center marks of the CRT using the
5