ALIGNMENT PROCEDURE
Standard Check point
1.Power source : 100 - 240Vac, 50/60Hz.
2.Aging : Take at least 20 minutes
3.Signal
Video input : Analog 0.7Vpp 75Ω terminal positive polarity
Synchronizing : acceptable negative or positive at TTL level
Max. Resolution : 1024 x 768 a 75Hz Frequency
Horizontal : 30KHz - 62KHz
Vertical : 50Hz - 75Hz (available only non interlace mode)
Adjustment
1.Smart scaling set to 69%.
2.Contrast set to 90%
3.Brightness set to 50%
4.Switching to factory alignment mode
Press power key with Brightness left key at the power off status.
5.Video level adjustment
Receive stair pattern of 16 step (doesn’t care any mode).
Readjust coarse R, G, B in TDA8752 menu before saturaton point.
6.Set up the tracking
See the user’s manual at page 8th.
7.Switching to user’s mode
If
*All of adjusted data stores by fade out of OSD.
14