Dakota Digital UTV-1200 manual Troubleshooting, Gauge Wire Color Chart

Models: UTV-1200

1 6
Download 6 pages 10.28 Kb
Page 5
Image 5
TROUBLESHOOTING

OPTION – DIM OUT

The dim out option allows the dim output to be turned on or off. The dim output is used if you have installed other Dakota Digital gauges and would like this gauge to also control the dimming of these gauges. If the dim out option is turned on, 12v is sent out on the dim out wire when the gauge is dimming. In this mode, the gauge will be either in dim mode or full brightness mode.

If no other gauges are to be dimmed, this option can be set to off. In this mode the gauge will fade when dimming and gauge dimming will be less noticeable.

TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

Gauge does not light up

Gauge has bad ground or power

Check connections to wiring harness and check

 

 

wiring harness and gauge wires for pinched or

 

 

broken wires.

Speed reads incorrectly

Speedometer needs to be recalibrated

See setup for speed calibration instructions.

Gauge does not dim

Dim level is set to off or set too low

Set dim level to higher level (see setup)

Gauge is always dim

Dim level is set too high

Set dim level to lower level (see setup)

 

Light sensor over left switch is covered

Make sure left side of lens is not covered.

 is displayed in fuel or

No sender connected.

Check proper connection to sender. Check for

oil display

 

broken or pinched sensor wires.

 is displayed in fuel or

Sensor wire is shorted to ground.

Check sensor wire harness for correct connection

oil display.

 

to sensor. Check for pinched or broken sensor

 

 

wire harness.

SERVICE DUE is scrolled

One of the countdown service meters

Perform service and reset service meter by

in the message center

has reached zero

holding right switch when service meter is

 

 

displayed. If service meter operation is not

 

 

desired, disable service meter by setting to  in

 

 

the setup menu.

ERR 01 to ERR 99 is

The Rhino engine computer is sending

See your Yamaha dealer for appropriate service.

displayed in the message

error codes to the gauge.

 

center

 

 

ERR B.1is displayed in

Gauge has poor bus connection to

Check for good connection to gauge harness.

message center

Rhino engine computer.

 

ERR B.2is displayed in

Bus wire is always in high state.

Check for shorts to 12V on bus wire.

message center

Gauge bus circuit damaged.

Repair needed.

 

ERR B.3is displayed in

Bus wire is shorted to ground.

Check for shorts to ground on bus wire. Check for

message center

 

proper connection to Rhino harness.

GAUGE WIRE COLOR CHART

VIOLET / BLACK

Data bus

BLACK / RED

Keyed power

WHITE / BLUE

Ground

WHITE

Fuel sender

GREEN / BLUE

Constant power

page 5

MAN#650244:A

Page 5
Image 5