Danby DAC5210M, DAC5110M Operating Instructions, INSTALLATION INSTRUCTIONS cont’d, Fan Speeds

Models: DAC5110M DAC5210M

1 16
Download 16 pages 31.71 Kb
Page 6
Image 6
3) Completing the Installation (cont’d)

INSTALLATION INSTRUCTIONS (cont’d)

3) Completing the Installation (cont’d)

Carefully place the air conditioner into the window with the “L” shaped mounting bracket (on top) positioned in front of the upper window sash. The bottom of the cabinet should be positioned on the “recessed” portion of the window frame. Pull the window down until it rests just behind the front flange of the (top) “L” shaped mounting bracket (See Fig. 5).

Expand the shutter frames (fully) on each side and secure the top of the frames to the window sash using one 3/4” screw on each side and one in the “L” shaped mounting bracket (Fig. 5).

Secure the shutter clamp on each side of the (lower) shutter and secure to window sill using one 3/4” screw on each side (Fig. 5).

Place the second foam sealing strip to fit the opening between the inside and outside windows, then attach the safety lock to the outside window frame using one 3/4” screw (See Fig. 6).

PLEASE NOTE: Window applications come in a variety of different styles. Therefore, it may be necessary to modify or improvise your particular installation.

Window sash

3/4” screws

“L” Shaped

Mounting

Bracket

Fig. 5

Shutter clamps

Safety Lock

Foam Seal

3/4” screw

Fig. 6

OPERATING INSTRUCTIONS

SELECTOR SWITCH: The selector switch controls fan speed and/or cooling speed. To set desired cooling temperature, simply rotate the SELECTOR knob to the appropriate setting.

FAN SPEEDS:

LOW FAN OPERATING INSTRUCTIONS will circulate air at minimum speed without cooling.

HIGH FAN FAN SPEEDS: will circulate air at maximum speed without cooling.

COOLING MODES:

LOW COOL COOLING MODES: provides cooling with minimum air circulation. Recommended for night-time use.

HIGH COOL Thermostat provides cooling with maximum air circulation. Recommended for quick cooling or for extremely hot days. Once room is cooled, reduce setting to LOW COOL.

OFF shuts-down the unit completely

NOTE: Always allow 3 minutes before switching from one mode to another.

THERMOSTAT: The thermostat automatically controls the (compressor) cooling cycle and maintains the selected room temperature. To set the thermostat, rotate the thermostat knob to the desired cooling setting (1 warmest

-7 coldest). The fan motor will continue to operate after the compressor (cooling) has cycled off. This is normal.

Manual backgroundWhen using FAN control, turn selector switch slowly, allowing unit to adjust. When using THERMOSTAT, be sure to allow three minutes before changing temperature. Adjusting too quickly may cause compressor to overload.

Thermostat

Selector

Switch

5

Page 6
Image 6
Danby DAC5210M Operating Instructions, INSTALLATION INSTRUCTIONS cont’d, Completing the Installation cont’d, Fan Speeds