INSTALLATION INSTRUCTIONS (cont’d)

3) Completing the Installation (cont’d)

Carefully place the air conditioner into the window with the “L” shaped mounting bracket (on top) positioned in front of the upper window sash. The bottom of the cabinet should be positioned on the “recessed” portion of the window frame. Pull the window down until it rests just behind the front flange of the (top) “L” shaped mounting bracket (See Fig. 5).

Expand the shutter frames (fully) on each side and secure the top of the frames to the window sash using one 3/4” screw on each side and one in the “L” shaped mounting bracket (Fig. 5).

Secure the shutter clamp on each side of the (lower) shutter and secure to window sill using one 3/4” screw on each side (Fig. 5).

Place the second foam sealing strip to fit the opening between the inside and outside windows, then attach the safety lock to the outside window frame using one 3/4” screw (See Fig. 6).

PLEASE NOTE: Window applications come in a variety of different styles. Therefore, it may be necessary to modify or improvise your particular installation.

Window sash

3/4” screws

“L” Shaped

Mounting

Bracket

Fig. 5

Shutter clamps

Safety Lock

Foam Seal

3/4” screw

Fig. 6

OPERATING INSTRUCTIONS

SELECTOR SWITCH: The selector switch controls fan speed and/or cooling speed. To set desired cooling temperature, simply rotate the SELECTOR knob to the appropriate setting.

FAN SPEEDS:

LOW FAN will circulate air at minimum speed without cooling.

HIGH FAN will circulate air at maximum speed without cooling.

COOLING MODES:

LOW COOL provides cooling with minimum air circulation. Recommended for night-time use.

HIGH COOL provides cooling with maximum air circulation. Recommended for quick cooling or for extremely hot days. Once room is cooled, reduce setting to LOW COOL.

OFF shuts-down the unit completely

NOTE: Always allow 3 minutes before switching from one mode to another.

THERMOSTAT: The thermostat automatically controls the (compressor) cooling cycle and maintains the selected room temperature. To set the thermostat, rotate the thermostat knob to the desired cooling setting (1 warmest

-7 coldest). The fan motor will continue to operate after the compressor (cooling) has cycled off. This is normal.

When using FAN control, turn selector switch slowly, allowing unit to adjust. When using THERMOSTAT, be sure to allow three minutes before changing temperature. Adjusting too quickly may cause compressor to overload.

Thermostat

Selector

Switch

5

Page 6
Image 6
Danby DAC5210M, DAC5110M Operating Instructions, Completing the Installation cont’d, FAN Speeds, Cooling Modes

DAC5110M, DAC5210M specifications

The Danby DAC5110M and DAC5210M are two versatile air conditioning units designed to provide effective cooling solutions for residential and small commercial spaces. Both models come equipped with a range of features and technologies that enhance their functionality, efficiency, and user-friendliness.

The DAC5110M is a compact 5000 BTU window-mounted air conditioner that is ideal for single rooms or small spaces up to 150 square feet. Its lightweight design makes installation a breeze, and it fits easily into most standard windows. This model is equipped with a mechanical thermostat that allows users to select their desired temperature easily. The unit also features a 2-speed fan and a 2-way air direction control, providing flexibility in airflow distribution.

On the other hand, the DAC5210M is a more powerful 5200 BTU window air conditioner that can cool areas up to 250 square feet. Like the DAC5110M, it also offers a mechanical thermostat and adjustable fan speeds, but it includes additional features such as a 24-hour programmable timer, which allows users to set the unit to turn on or off at specific times, promoting energy efficiency.

Both models are equipped with multiple cooling and fan speeds, allowing users to customize their comfort level according to their specific preferences. The energy-efficient design of these air conditioners complies with Energy Star requirements, ensuring that they consume less electricity compared to traditional units. This not only helps in reducing energy bills but also minimizes the environmental impact.

Another significant feature of the Danby DAC5110M and DAC5210M is the easy-to-clean, washable air filter, which helps maintain good air quality by trapping dust and allergens. Regular maintenance of the filter extends the lifespan of the unit and ensures optimal performance.

Moreover, both units are designed with user convenience in mind. Each model includes a remote control option, allowing users to adjust settings from across the room without needing to get up. The quiet operation of these air conditioners is another advantage, making them suitable for bedrooms and workspaces where noise can be disruptive.

In conclusion, the Danby DAC5110M and DAC5210M are commendable additions to any home or small office space. With their efficient cooling capacities, user-friendly features, and eco-friendly designs, they offer great value for those seeking reliable air conditioning solutions. Both models exemplify Danby’s commitment to quality, performance, and customer satisfaction.