Appendix A

Technical Specifications

Optical and Read Performance Parameters

Parameter

 

Specification

 

 

 

 

 

 

Scan Volume

 

1147 cm3 / 70 in3

Scan Pattern

 

136 scan lines

 

 

Scan Rate

1760 Digital Scan Lines/second

 

 

 

 

Minimum Resolution

 

 

5 mil

 

 

 

 

Depth of Field

Code Size

 

Depth of Field

(100% UPC Labels)

 

 

 

 

 

 

 

 

 

5 mil

 

25.4 - 57.2mm / 1.0 - 2.25”

 

 

 

 

 

7.5 mil

 

12.7 - 69.9mm / 0.5 - 2.75”

 

 

 

 

 

10 mil

 

12.7 - 139.7mm / 0.5 - 5.5”

 

 

 

 

 

13 mil

 

12.7 - 165.1mm / 0.5 - 6.5”

 

 

 

 

 

20 mil

 

12.7 - 184.2mm / 0.5 - 7.25”

 

 

 

 

Minimum Print Contrast Ratio

 

25%

 

 

 

 

Skew (Yaw)

 

 

± 75

 

 

 

 

Pitch

 

 

± 65

 

 

 

Roll

 

Between 0 and 360

 

 

 

 

Electrical Parameters

Parameter

Specification

 

 

 

 

Operating Voltage

Input voltage 4.5 to 14 VDC

 

 

Input Current

<350mA

Operating (idle)

Operating (label read)

<450 mA

Surge Current (<30 ms)

<600 mA

 

 