Datel High Efficiency, AC/DC Instrumentation Power, DMS-PS-CM Series, AC Input, DC Outputs

Models: DMS-PS-CM

1 8
Download 8 pages 41.33 Kb
Page 2
Image 2
High Efficiency, AC/DC Instrumentation Power

DMS-PS-CM Series

High Efficiency, AC/DC Instrumentation Power

Supplies with Individually Isolated Outputs

Performance/Functional Specifications

Typical at TA = +25°C and VIN = 85-264V @47-63Hz

AC Input

 

Input Voltage Range, All models

85-264V @47-63Hz

 

 

Input Current (115V/230V, typ.):

 

5-Watt Models

0.15A/0.07A

10-Watt Models

0.3A/0.13A

16-Watt Models

0.33A/0.16A

 

 

Inrush Current (All models, typical peak):

 

@115Vac

14.1A

@230Vac

32.5A

 

 

Isolation (Min.):

 

Output V1 to AC Input

3000Vac

Outputs V2 & V3 to AC Input

3000Vac + 1000Vdc

AC Input to Frame Ground

1500Vac

Output V1 to Frame Ground

500Vac

Outputs V2 & V3 to Frame Ground

500Vac + 1000Vdc

Outputs V2 & V3 to Output V1

1000Vdc

Output V2 to Output V3

2000Vdc

 

 

Frame Ground Leakage Current (Max.):

 

@115Vac

0.5mA

@230Vac

3.5mA

 

 

Switching Frequency (Typical):

 

V1 (5W and 10W models)

75kHz

V1 (16W models)

83kHz

V2 & V3 (All models)

100kHz

 

 

Line Fuse (Built-in)

1A/250Vac, 5 x 20mm, meeting

IEC60127-2, sheet 3 specification

for time lag fuses

(slow-blow)

 

 

 

AC Mains Terminal Block (TB4):

14-20AWG (2.5 to 0.5mm2),

Wire Size & Type

 

solid or stranded

Insulation Strip Length

0.25 inches (6.4mm)

Screw Tightening Torque

4.4 pound-inches (0.5Nm)

Rated Voltage

630V (VDE 0110-V. Group 2);

250V (VDE 0110-V. Group 3)

 

 

 

EMI (All models)

Meets CISPR Pub. 22 & FCC

Class B

 

 

 

Safety Approvals

Pending

 

 

DC Outputs

 

Line Regulation (All outputs)

±0.1% (max)

 

 

Load Regulation:

 

V1 (All models)

±2%

V2 & V3 (All models)

±0.2% (max)

 

 

Output Accuracy (Max.):

 

V1 (All models)

±2.0%

V2 & V3 (All models)

±2.5%

 

 

Hold-Up Time (47-63Hz):

 

@115Vac

20mSec. typ.

@230Vac

80mSec. typ.

 

 

Noise & Ripple

 

(All models, 20MHz bandwidth):

See Noise & Ripple graphs

V1

40mVp-pk (typ.)

V2 & V3

8mVp-pk (typ.)

 

 

Transient Response

See Transient Response graphs

 

 

www.murata-ps.com

DC Outputs (continued)

 

Efficiency (Typ.@ 120Vac, full load):

 

Single Output Models

75%

Dual Output Models

73%

Triple Output Models

71%

 

 

DC-Output Terminal Blocks (TB1, TB2, TB3):

16-20AWG (1.5 to 0.5mm2),

Wire Size &Type

 

solid or stranded

Insulation Strip Length

0.25 inches (6.4mm)

Screw Tightening Torque

3.6 pound-inches (0.4Nm)

 

 

Short Circuit Protection (All outputs)

Foldback, self-recovering

 

 

Overvoltage Protection V1 (max.)

134% x Vout

 

 

Environmental

 

Operating Temperature

0 to +50°C @ full rated power;

–25 to +70°C @ 50% rated power

(see Figure 3)

 

 

Storage Temperature

–40 to +85°C

 

 

Cooling

Free air convection with derating

 

(see Figure 3 and Technical

Notes)

 

 

 

Humidity (Non-condensing)

0 to 85%

 

 

Physical

 

Dimensions

See Mechanical Specifications

 

 

Weight:

 

5 Watt Models

5.8 ounces (165 grams)

10 Watt Models

6.9 ounces (195 grams)

16 Watt Models

7.9 ounces (223 grams)

 

 

Case Materials:

 

Outer Case

ABS, UL94 5VA

DC/DC Modules

Phenolic, UL94 V-0

AC/DC Modules

Plastic, UL94 V-1

 

 

All models will also operate from a regulated and filtered 110 to 340Vdc input.

Unless otherwise specified, load regulation is measured with the output under test undergoing a load change of 100% to 50% at nominal line input and, when applicable, with all other outputs operating at 50% of rated load.

Transient response is defined as the output returning to within its specified tolerance in 10ms or less, following a 90% load change.

Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000

MPM_DMS-PS-CM_B01Page 2 of 8

Page 2
Image 2
Datel DMS-PS-CM manual High Efficiency, AC/DC Instrumentation Power, Supplies with Individually Isolated Outputs, AC Input