Theory of Operation
THE FUEL SYSTEM
The gas supply attaches to the heater by a minimum 3/4 inch i.d. hose or flexible connector. User must supply hose or flexible connector. The length should be no more than 10 feet long. The natural gas moves through the regulator and out the nozzle.
THE IGNITION SYSTEM
The piezo ignitor lights the pilot fuel supply.
THE AUTOMATIC CONTROL SYSTEM
The automatic control valve shuts off the heater if the flame goes out.
Product Identification
Top
Shell
Emitter
Ignitor
Electrode
Nozzle
Pilot Burner
Main
Burner
Tube
Thermocouple
Regulator
Automatic Control
Valve Button
Piezo Ignitor
Button
Base
ValveAssembly
Inlet
Figure 2 - Product Identification
Specifications
| Output |
| Fuel | Size | Weight |
|
Model | Rating Btu/Hr | Fuel | Consumption | LxWxH(Inches) | (pounds) | Manifold Pressure |
|
|
|
|
|
|
|
3VH19 | 100,000 | Natural | 100 Cubic Feet/Hour 16 x 16 x 29.5 | 23 (Heater) | 4" w.c. | |
|
| Gas Only |
|
| 27 (Shipping) |
|
|
|
|
| |||
Maximum Supply | Minimum Supply |
|
|
| ||
Pressure to Regulator | Pressure to Regulator |
|
|
| ||
1/2 PSI |
| 6" w.c. |
|
|
|
|
®
3
Version B - For Reduction | G016.J |