Dayton Operating Instructions and Parts Manual | 3VH19 |
Dayton® Natural Gas
Construction Heater
Troubleshooting Chart
|
|
| Never attempt to service heater while it is connected to gas supply, operating, or hot. Severe burns can |
| ||
|
|
|
| |||
|
|
| occur. |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Symptom | Possible Cause(s) | Corrective Action |
| ||
| Pilot fails to light | 1. Natural gas supply valve closed on gas | 1. Open natural gas supply valve slowly |
| ||
|
|
|
| supply |
|
|
|
|
|
|
| 2. Allow several minutes to purge air with |
|
|
|
|
| 2. Air in gas line | automatic control valve button depressed |
|
|
|
|
| 3. Blockage in pilot orifice | 3. Replace pilot orifice |
|
|
|
|
| 4. Piezo ignition system not sparking | 4. Adjust ignitor electrode gap to .120". |
|
|
|
|
|
| Check wire lead for damage. Replace |
|
|
|
|
|
| piezo ignitor and/or ignitor electrode as |
|
|
|
|
|
| necessary |
|
|
|
|
|
| ||
| Pilot lights but goes out when control | 1. Not enough | 1. Relight, hold automatic control valve |
| ||
| valve knob is released |
| button in 45 seconds |
| ||
|
|
|
| 2. Low gas pressure | 2. Check natural gas for proper gas supply |
|
|
|
|
| 3. Thermocouple loose or needs to be | 3. Tighten connection or replace thermo- |
|
|
|
|
| replaced | couple |
|
|
|
|
| 4. Control valve needs to be replaced | 4. Replace control valve |
|
|
|
|
|
| ||
| Maximum Burn rate is low; | 1. Main burner valve not fully open | 1. Fully open main burner valve by turning |
| ||
| Emitter not glowing |
| the valve handle towards ON position |
| ||
|
|
|
|
| until it stops |
|
|
|
|
| 2. Plugged gas orifices |
|
|
|
|
|
|
| 2. Replace gas orifice |
|
|
|
|
| 3. Low gas pressure |
|
|
|
|
|
|
| 3. Consult natural gas supplier; check |
|
|
|
|
|
| regulator output |
|
|
|
|
|
| ||
| Soot forming inside heater, | 1. Main burner valve not fully open | 1. Adjust main burner valve slowly |
| ||
| flame 100% yellow |
| towards ON position |
| ||
|
|
|
| 2. Low gas pressure | 2. Consult natural gas supplier |
|
|
|
|
|
|
|
|
Flames are extremely high. Coming out of louvers
1.Unit was connected to LP gas instead of natural gas
1.Check gas source, replace with natural gas supply