DriveRack™ | Appendix A |
A.2 Factory Reset
In the unfortunate event that a reset is required, the DriveRack™ units offer you the option of performing a “Soft” or “Hard” reset. The Soft Reset resets everything except user programs. The Hard Reset Procedure will reset all program- mable information back to the factory defaults.
480 and 480R Factory ("Hard") Reset
•Press and Hold the STORE button on
"! HARD RESET?"
•Pressing the PREV PAGE button will start a Factory Reset (All User Programs will become copies of the Factory Programs, all Utility settings will be defaulted, and all Security settings will be defaulted)
Pressing the PROGRAM button will abort the Factory Reset sequence and the unit will reset normally.
480 and 480R Factory ("Soft") Reset.
Press and Hold the OTHER button at
•Pressing the PREVPAGE button will start a System Reset (All Utility settings will be defaulted.)
•Pressing the PROGRAM button will abort the System Reset sequence and the unit will reset normally.
481 and 482 Factory ("Hard") Reset
•Press and hold the ID DOWN button on
"HARD"
•Pressing the PROGRAM UP button will start a Factory Reset (All User Programs will become copies of the Factory Programs, all Utility settings will be defaulted, and all Security settings will be defaulted)
Pressing any other button will abort the Factory Reset sequence and the unit will reset normally.
481 and 482 Factory ("Soft") Reset.
•Press and Hold the ID UP button on
"SOFT "
•Pressing the PROGRAM UP button will start a System Reset (All Utility settings will be defaulted.) Pressing any other button will abort the System Reset sequence and the unit will reset normally.
A.3 Power Up Quick Key Options
The DriveRack™ units offer several “Quick Key” options for initial power up and are as follow:
480 and 480R Power-Up Output Mute
Press and hold any of the mute buttons at
480 and 480R Change Initial Program Number
Press and hold <PROGRAM> at
"Use Wheel1 to" - "Change Restart" - "Program Number" Turning the PARAMETER 1 knob will select the program you wish to load at initial reset.
Press the PROGRAM button again when the selection is complete. Normal resetting will continue.
481 and 482 Power-Up Output Mute
Press and hold any of the mute buttons at
481 and 482 Change Initial Program Number
Press and hold the PROGRAM DOWN button at
®
DriveRack™ User Manual | 93 |
|
|