PIPE DRAIN
The minimum inside diameter of the pipe drain
should be 30mm and the pipe should be able to
drain 30 litres per minute.
The top lip of the pipe should be at least
860mm (B) above floor level and not higher
than 1300mm.
B
INLET HOSES
Connect the respective inlet hoses to the hot and cold water taps and to the machine’s inlet
fittings. (see sketch es below) The hot water inlet is on the left and the cold water inlet on
the right.
CONVENTIONAL TAPS
1
Pull down the collar of the
inlet valve to separate it
from the water tap adaptor.
2
Loosen the four screws in
the water tap adaptor.
3
Fit the tap adaptor to the tap so
that the rubber seal fits snugly.
Then tighten the four screws
evenly.
4
Remove the tape and screw
(B) into (A).
5
Connect the inlet hose to
the water tap adaptor.
6
Attach the other end of the
hose to the machine inlet by
turning it clockwise until tight.
A
B