Installation

Installation

Installation sequence;

1.Extractor unit / chimney brackets.

2.Top chimney duct.

3.Bottom chimney duct.

Carefully remove the extractor hood and the components from the packaging.

Carefully remove the protective film.

Remove the grease filters (see page 8).

Draw a fine vertical line on the wall from the rear-centre of the hob to the ceiling.

Draw another line, horizontal this time, where the bottom edge of the hood should be.

(A minimum clearance height of 650 mm is required when installed above a built in electric hob or 700 mm when installed above a built in gas hob).

For mounting the chimney bracket, drill 2 holes, 5 mm diameter and 45 mm deep into the wall.

For mounting the extractor hood, drill 2 holes, 8 mm in diameter and 60 mm deep as indicated on the mounting diagram.

Push the 5 mm wall plugs through the holes in the chimney mounting brackets. Insert the plugs into the drilled holes together with the chimney mounting bracket and fasten securely.

Push the 8 mm wall plugs into the 8 mm holes ensuring that they are flush with the wall.

Partially screw two 6 mm screws into the two top wall plugs leaving them to protrude about 10 mm.

Lift and hook the extractor hood over and onto the two protruding screws through the key-hole slots provided at the top of the extractor hood frame.

Place slotted washers between the extractor hood frame and the protruding screw heads.

Before fitting the chimneys, connect up the outlet ducting (if required) and insert the fitted plug into the wall socket.

Remove the protective film from the chimney ducting taking care not to damage the polished stainless steel surface.

Fit the upper chimney duct section (the one with louvre outlets) to the ceiling mounting bracket using the screws supplied.

The lower duct fits between and over the extractor hood motor assembly and the upper duct. Take care not to scratch or damage the hood and upper duct surfaces.

Loosely attach the lower duct bottom edge to the hood by four self tapping screws through four holes on the inside of the extractor hood.

Fit the lower duct to the lower chimney wall mounting bracket and tighten the four self tapping screws on the inside of the extractor hood.