Defy Appliances DHD 394 Technical Specifications, Error codes, Model, Plate power rating W

Models: DHD 394

1 12
Download 12 pages 7.53 Kb
Page 9
Image 9
Technical Specifications

Technical Specifications

Model

 

DHD 394

 

 

 

Volts

 

220V –240V 50Hz~

Amperes

 

28

 

 

Plate power rating (W)

 

Front cooking zone left

140, 1200

Front cooking zone

right

140, 1200

Rear cooking zone

right

180, 1800

Rear cooking zone

left

210/120, 2200/750

 

 

 

Total power (W)

 

6400

 

 

 

Type of switch

 

Electronic sensors

Width

 

580 mm

Depth

 

510 mm

 

 

 

Error codes

ERROR CODE

ERROR DESCRIPTION

WHAT TO DO

 

 

 

ER03

Continuous holding down of sensors.

CONTACT YOUR DEFY SERVICE

& permanent tone

Control unit cuts off after 10 seconds.

CENTRE AND SPECIFY THE ERROR

CODE

 

Water or a cooking utensils may be posi

 

tioned over the control unit causing inter

 

 

ference.

 

 

 

 

ER21

Overheating: The control unit switches

CONTACT YOUR DEFY SERVICE

 

off in order to avoid damage to the unit

CENTRE AND SPECIFY THE ERROR

 

CODE

 

 

 

 

 

U400

Secondary voltage of the power unit is

1 CONTACT YOUR DEFY SERVICE

 

too high. Control unit switches off after

CENTRE AND SPECIFY THE ERROR

 

CODE

 

one second and permanent tone is emit

 

2 CONTACT AN ELECTRICIAN TO

 

ted.

CHECK THE MAINS POWER SUPPLY

 

 

 

ER22

Touch pad evaluation is defective. Con

CONTACT YOUR DEFY SERVICE

 

trol unit switches off after 3.5—7 se

CENTRE AND SPECIFY THE ERROR

 

CODE

 

conds. Short circuit or there is a problem

 

with the sensor evaluation range

 

 

 

 

ER36

NTC value is not within its specification.

CONTACT YOUR DEFY SERVICE

 

(Value < 200mV or > 4.9V; Control unit

CENTRE AND SPECIFY THE ERROR

 

CODE

 

cuts off. Short circuit or cut off at NTC

 

 

 

 

 

ER20

Flash failure. Micro controller faulty

CONTACT YOUR DEFY SERVICE

 

 

CENTRE AND SPECIFY THE ERROR

 

 

CODE

 

 

 

ER40

Secondary operational voltage is too

CONTACT YOUR DEFY SERVICE

 

low. (1.8V <U Power fail< 2.9V) Primary

CENTRE AND SPECIFY THE ERROR

 

PTC too hot

CODE

 

 

 

 

 

PAGE 9 OF 12

Page 9
Image 9
Defy Appliances DHD 394 Technical Specifications, Error codes, Model, Plate power rating W, Error Code, Error Description