Shelleybasic by Delfield Service & Installation Manual
Installation
Location
Units represented in this manual are for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded model may weigh as much as 3000 pounds! Reinforce the floor as necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide good air circulation inside and out. Be sure that the exterior of the unit has access to ample air. Avoid hot corners and locations near stoves and ovens. It is suggested the rear of the unit be no less than two inches from any wall, partition or any other object which will restrict exhaust air flow.
Unit requires that the sides and bottom are not any closer than 3” to any combustible material.
D A N G E R
Leveling
A level cabinet looks better and will perform more efficiently when the doors line up with the door frames properly, the cabinet will not be subject to undue strain and the corners of the shelves will not move around on the supports. A level heated unit will maintain an equal water depth when water is used in the wells. Use a level to make sure the unit is level from front to back and side to side.
Stabilizing
All models are supplied on casters for your convenience, ease of cleaning underneath and for mobility.
The unit must be installed in a stable condition with the front wheels locked, locking the front casters after installation is the owner’s responsibility.
Plumbing
Refrigerated units have a drain that exits the unit on the bottom and is located on the operator’s left side. Standard units on casters or legs will have a bronze gate valve that fits a standard garden hose. Drain connections are on the operator side below the pan in the open shelf area.
| Moisture collecting from improper drainage | |
| can create a slippery surface on the floor | |
| and a hazard to employees. It is the owner’s | |
CAUTION | responsibility to provide a container or | |
outlet for drainage. | ||
|
Electrical Connection
A standard unit is provided with a power cord and grounded plug.
The unit should be plugged into a receptacle with its own circuit protection that matches the amperage of the plug.
Connections must be made in accordance with all applicable local codes and/or the National Electrical Code. Refer to the amperage data on pages
On
1.Performing maintenance functions.
2.Cleaning the refrigerated cabinet area.
3.Performing service or repair functions.
Under no circumstances should a refrigerated unit be operated without the louvered panel in place.