Delfield®

Specification Line®

Self-Contained Glass Door Refrigerated Roll-In

Project ___________________________________

Item _____________________________________

Quantity _ ________________________________

CSI Section 11400

Approved _ _______________________________

Date _____________________________________

Specification

Models

One section

Two section

Three section

 

SSRRI1-G

SSRRI2-G

SSRRI3-G

Stainless exterior and interior glass full door

SARRI1-G

SARRI2-G

SARRI3-G

Stainless exterior and aluminum interior glass full door

SMRRI1-G

SMRRI2-G

SMRRI3-G

Stainless front aluminum exterior and interior glass full door

SSRRI2-G

Standard Features

Stainless steel interior and exterior (SS)

Stainless steel exterior, aluminum interior (SA)

Aluminum interior and exterior, stainless front (SM)

Built in door locks with heavy duty strikes

Pressure relief valve is standard to prevent door vapor lock

Exterior digital thermometer with high/ low temperature alarm

Easy to use electronic control

• Easy access “flip up” shroud

10’ attached cord and plug on 115V units

Stainless steel breaker strips

High density foamed in place environmentally friendly, Kyoto Protocol Compliant, Non ODP (Ozone Depletion Potential), Non GWP (Global Warming Potential) polyurethane keeps energy costs low

Energy savings door heater switch

Two year parts & labor warranty

Five year compressor warranty

Options &

Accessories

Security (prison) package

Incandescent light

Door field rehingability

Stainless steel back

Laminate on front, sides and back

Bottom mount electrical

Stainless steel banking strip

Heat shield end

230-50-1 electrical

220-60-1 electrical

Line®: Glass Door

Specifications

Exterior: SS and SA models shall have corrosion resistant stainless steel exterior cabinet sides, front and shroud. SM models shall have corrosion resistant aluminum on exterior cabinet sides and will have stainless front and shroud. All units shall have the upper shroud hinged with a gas assist stay open feature to provide easy access to the refrigeration system.

Interior: Cabinet interior shall be corrosion resistant stainless steel (SS models) or heavy gauge aluminum (SA and SM models). Bottom and top surfaces shall be die stamped to provide radius corners and recessed floor. Mounted to the interior ceiling, the interior fluorescent light is controlled automatically through a switch mounted in the hinge assembly to protect against breakage. Door openings are protected with heavy gauge stainless steel breaker strips. An air duct shall be mounted to the ceiling assuring low velocity, even air movement throughout the cabinet interior.

Each section can accommodate a 28 1/2” x 27 1/4” x 72” cart.

Doors: Double paned tempered thermopane glass. Constructed with a combination of extruded aluminum and PVC. Each door has two edgemount, self-closing, cam lift style hinges. Doors can be removed from the cabinet without the use of tools. Door handle is continuous along vertical dimension of the door. Door gaskets are magnetic and mount to the door, snapping in place and removable with out tools. Keyed door lock is mounted to the door. Lock engages into a heavy duty strike mounted to the cabinet face.

Refrigeration system: All components are mounted to the exterior of the cabinet ceiling, outside the food zone and are assembled

as one piece and can be removed as one piece. Environmentally friendly R404A refrigerant is used. The system has the capability of maintaining between 27ºF and 40ºF in heavy use food service operations. Refrigerant is metered using a highly responsive thermostatic expansion valve. System is controlled using Delfield’s ACT-Advanced Control Technology electronic temperature control, which provides improved pull down times, reduces compressor cycling and longer compressor life with lower energy consumption.

Control system uses adaptive defrost to assure evaporator coil is free of ice and is operating at optimum efficiency. Evaporator condensate is eliminated using an energy efficient hot gas system.

Electrical: Standard Electrical on one and two section units shall be 115V, 60 Hz single phase. A 10’ cord and plug is supplied and attached to a junction box mounted on the exterior top of the cabinet. Three section units shall be 115/208-230 and will require hardwire connections.

Refrigerated Roll-In

980 S. Isabella Rd.

Mt. Pleasant, Michigan 48858

Phone: 800-733-8948 or 989-773-7981

Fax: 800-669-0619

www.delfield.com