Compact Refrigerators

STANDARD LABOR GUIDELINES TO RE- PAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT

Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.

A maximum of 1-hour is allowed to diagnose a defec- tive component.

A maximum of 1-hour is allowed for retrieval of parts not in stock.

A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.

Overtime, installation/start-up, normal control adjust- ments, general maintenance, glass breakage, freight dam- age, and/or correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work Authorization from Delfield. You must submit the number with the service claim.

LABOR OF 1-HOUR IS ALLOWED TO REPLACE:

• Thermostat

• Evaporator/Condenser Fan Motor and Blade

Hi-limit/Thermal Protector Switch

• Door Hinges, Locks, and Gaskets

• Compressor Start Components and Overload Protector

 

LABOR OF 2 HOURS IS ALLOWED TO REPLACE:

• Drawer Tracks/Cartridges

• Locate/Repair a Leak

• Defrost Heater

 

LABOR OF 3 HOURS IS ALLOWED TO REPLACE:

• Condenser or Evaporator Coil

• Hot gas condensate evaporator

LABOR OF 4 HOURS IS ALLOWED TO REPLACE

Compressor

This includes recovery of refrigerant and leak check.

$55.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings, solder, brazing rod, nitrogen, or similar fees.)

REFRIGERANTS

R404A A maximum of $15.00/lb. or $1.00/oz. will be reimbursed.

17