10
Getting Started With Your System
Power
AC power supply (per power supply)
Watt age
750 W (optional redundant power supply)
Volta ge
100–240 VAC, autoranging, 50–60 Hz
Heat dissipation
2450 BTU/hr maximum
Maximum inrush current
Under typical line conditions and over the
entire system ambient operating range,
the inrush current may reach 55 A per
power supply for 10 ms or less.
Batteries
System battery
CR 2032 3.0-V Lithium coin cell
Physical
Height 8.67 cm (3.42 inches)
Width 44.52 cm (17.53 inches)
Depth 66.46 cm (26.17 inches)
Weight (maximum configuration) 29.0 kg (63.8 lbs)
Weight (empty) 15.85 kg (34.87 lbs)
Environmental
NOTE:
For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temp era ture
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE:
For altitudes above 2950 ft,
themaximum operating temperature is
derated1ºF/550 ft.
Storage
–40° to 65°C (–40° to 149°F) with a
maximum temperature gradation
of20°C per hour