Getting Started With Your System
11
Relative humidity
Operating
20% to 80% (noncondensing) with
amaximum humidity gradation
of10% per hour
Storage
5% to 95% (noncondensing)
Maximum vibration
Operating
0.26 G at 5–350 Hz for 15 min
Storage
1.54 G at 10–250 Hz for 15 min
Maximum shock
Operating
One shock pulse in the positive z axis
(onepulse on each side of the system) of
31G for 2.6 ms in the operational orientation
Storage
Six consecutively executed shock pulses
inthe positive and negative x, y, and z axes
(onepulse on each side of the system)
of71 G for up to 2 ms
Altitude
Operating
–16 to 3048 m (–50 to 10,000 ft)
NOTE:
For altitudes above 2950 ft,
themaximum operating temperature
isderated 1ºF/550 ft.
Storage
–16 to 10,600 m (–50 to 35,000 ft)
Airborne Contaminant Level
Class
G2 or lower as defined by ISA-S71.04-1985
Environmental (continued)