* — SNMP and SMTP ports can be configured, if the firmware version is 1.5x.5x or greater.
iDRAC6 for Rack and Tower Servers
Table 16. Supported Protocols and Ports
Port Number | Protocols | Configurable |
|
|
|
22 | SSH | Yes |
|
|
|
23 | Telnet | Yes |
|
|
|
25 | SMTP | No |
|
|
|
53 | DNS | No |
|
|
|
68 | No | |
|
|
|
69 | TFTP | No |
|
|
|
80 | HTTP | Yes |
|
|
|
161 | SNMP Agent | No |
|
|
|
162 | SNMP Trap | No |
|
|
|
443 | HTTPS | Yes |
|
|
|
623 | RMCP/RMCP+ | No |
|
|
|
636 | LDAPS | No |
|
|
|
5900 | Virtual Console/Virtual Media | Yes |
|
|
|
3269 | LDAPS for global catalog (GC) | No |
|
|
|
iDRAC for Blade Servers
Table 17. Supported Protocols and Ports
Port | Protocols | Port Type | Version | Maximum | Directio | Usage | Configu |
Number |
|
|
| Encryption | n |
| rable |
|
|
|
| Level |
|
|
|
|
|
|
|
|
|
|
|
22 | Secure | TCP | 1.30 | In/Out | Secure CLI | Yes | |
| Shell (SSH) |
|
|
|
| management |
|
|
|
|
|
|
|
|
|
23 | Telnet | TCP | 1.0 | None | In/Out | Optional | Yes |
|
|
|
|
|
|
| |
|
|
|
|
|
| CLI |
|
|
|
|
|
|
| management |
|
|
|
|
|
|
|
|
|
25 | SMTP | TCP | 1.0 | None | In/Out | Optional | No |
|
|
|
|
|
| alert messages |
|
|
|
|
|
|
|
|
|
53 | DNS | UDP | 1.0 | None | In/Out | Dynamic DNS | No |
|
|
|
|
|
| registration of |
|
|
|
|
|
|
| host name |
|
|
|
|
|
|
|
|
|
24