Error Code Message Information
PCI1348 Message A PCI parity error was detected on a component at slot <
number
>.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1360 Message A bus fatal error was detected on a component at slot <
number
>.
Details System performance may be degraded, or system may fail to operate.
Action Cycle input power, update component drivers, if device is removable,
reinstall the device.
PDR0001 Message Fault detected on drive <
number
>.
Details The controller detected a failure on the disk and has taken the disk
offline.
Action Remove and re-seat the failed disk. If the issue persists, see Getting
Help.
PDR1016 Message Drive <
number
> is removed from disk drive bay <
bay
>.
Details The controller detected that the drive was removed.
Action Verify drive installation. Re-seat the failed drive. If the issue persists,
see Getting Help.
PST0128 Message No memory is detected.
Details System BIOS was unable to detect memory in the system.
Action Re-seat the memory modules. If the issue persists, see Getting Help.
PST0129 Message Memory is detected, but is not configurable.
Details System BIOS detected memory, but was unable to configure the
memory for system operation.
Action Compare system memory installation to supported system memory
configurations.
PSU0001 Message Power supply <
number
> failed.
Action Remove and reinstall the power supply. If the issue persists, see
Getting Help.
94