Error Code | Message Information |
|
| LCD Message | PSU <number> is absent. Check PSU. |
| Details | The supply has been removed or has failed. |
| Action | 1. Remove and reinstall the power supply. |
|
| |
|
| 2. Check cables and subsystem components in the system for |
|
| damage. |
|
| 3. If the issue persists, see Getting Help. |
PSU0031 | Message | Cannot communicate with power supply <number>. |
| ||
| LCD Message | Cannot communicate with PSU <number>. |
| Details | The power supply may operate, however power supply monitoring |
|
| will be degraded. System performance may be degraded. |
| Action | Remove and reinstall the power supply. If the issue persists, see |
|
| Getting Help. |
PSU1201 | Message | Power supply redundancy is lost. |
| ||
| Details | The power supply will try to operate in a degraded state. System |
|
| Performance and power redundancy may be degraded or lost. |
| Action | Check input power. Reinstall the power supply. If the issue persists, |
|
| see Getting Help. |
PSU1202 | Message | Power supply redundancy is degraded. |
| ||
| Details | The power supply will try to operate in a degraded state. System |
|
| Performance and power redundancy may be degraded or lost. |
| Action | Remove input power and reinstall supply at the next service window. |
PSU1203 | Message | The power supplies are not redundant. |
| ||
| LCD Message | Lost PSU redundancy. Check PSU cables. |
| Details | The current power operational mode is |
|
| power supply exception, a power supply inventory change, or a |
|
| system power inventory change. |
| Action | Check the event log for power supply failures. Review system |
|
| configuration and power consumption. |
PSU1204 | Message | The power supplies are not redundant. Insufficient resources to |
| ||
|
| maintain normal operations. |
| LCD Message | PSU redundancy degraded. Check PSU cables. |
113