Dell

8.12 Real-Time Clock (RTC)

The Ibex Peak contains a real-time clock with 256 bytes of battery-backed RAM.

The real-time clock performs two key functions: keeping track of the time of day and storing system data, even when the system is powered down. The RTC operates on a 32.768 KHz crystal and a 3 V battery.

The RTC also supports two lockable memory ranges. By setting bits in the configuration space, two 8-byte ranges can be locked to read and write accesses. This prevents unauthorized reading of passwords or other system security information.

The RTC also supports a date alarm that allows for scheduling a wake up event up to 30 days in advance, rather than just 24 hours in advance.

8.13 GPIO

Various general purpose inputs and outputs are provided for custom system design. The number of inputs and outputs varies depending on Ibex Peak configuration.

8.14 Enhanced Power Management

The Ibex Peak’s power management functions include enhanced clock control and various low- power (suspend) states (e.g., Suspend-to-RAM and Suspend-to-Disk). A hardware-based thermal management circuit permits software-independent entrance to low-power states. The Ibex Peak contains full support for the Advanced Configuration and Power Interface (ACPI) Specification, Revision 3.0a.

8.15 System Management Features

In addition to Intel AMT, the Ibex Peak integrates several functions designed to manage the system and lower the total cost of ownership (TCO) of the system. These system management functions are designed to report errors, diagnose the system, and recover from system lockups without the aid of an external microcontroller.

8.15.1TCO Timer

The Ibex Peak’s integrated programmable TCO (Total Cost of Ownership) timer is used to detect system locks. The first expiration of the timer generates an SMI# that the system can use to recover from a software lock. The second expiration of the timer causes a system reset to recover from a hardware lock.

8.15.2Processor Present Indicator

The Ibex Peak looks for the processor to fetch the first instruction after reset. If the processor does not fetch the first instruction, the Ibex Peak will reboot the system.

8.15.3Error Code Correction (ECC) Reporting

When detecting an ECC error, the host controller has the ability to send one of several messages to the Ibex Peak. The host controller can instruct the Ibex Peak to generate an SMI#, NMI, SERR#, or TCO interrupt.

PowerEdge R210 Technical Guide

36

Page 36
Image 36
Dell R210 manual Real-Time Clock RTC, Gpio, Enhanced Power Management, System Management Features, TCO Timer