Dell R420xr Environmental Temperature Continuous Operation, or 3117 ft, sunlight on the equipment

Models: R420xr

1 9
Download 9 pages 8.26 Kb
Page 8
Image 8
Environmental

Environmental

Temperature (Continuous Operation)

Temperature Ranges (for altitude less than 950 m

10 °C to 45 °C (50 °F to 113 °F) with no direct

or 3117 ft)

sunlight on the equipment.

Humidity Percentage Range

10% to 80% Relative Humidity with 26 °C (78.8

 

°F) maximum dew point.

Relative Humidity

 

Storage

5% to 95% RH with 33 °C (91 °F) maximum dew

 

point. Atmosphere must be non-condensing at

 

all times.

Vibration

 

Operating

MIL-STD-810G, Method 514.6, Figure 514.6D-9,

 

0.00220783 g2/Hz at 10-500 Hz (overall 1.04

 

Grms), 1 hour per axis

Non-operating

MIL-STD-810G, Method 514.6, Figure 514.6,

 

Procedure I, Category 4, Figure 514.6C-1 (US

 

highway truck vibration), Vertical: 5-500 Hz at

 

1.04 Grms, Transverse: 5-500 Hz at 0.204 Grms,

 

Longitudinal: 5-500 Hz at 0.740 Grms, 1 hour

 

per axis

Shock

 

Operating

MIL-STD-810G, Method 516.6, Procedure I,

 

20G for rotational hard drives and 40G for solid

 

state drives, 11 ms, saw tooth, 3 shocks, +/- per

 

axis

Non-operating

Maximum Altitude

Operating

Storage

Operating Altitude De-rating

Up to 35 °C (95 °F)

35 °C to 40 °C (95 °F to 104 °F)

40 °C to 45 °C (104 °F to 113 °F)

Particulate Contamination

MIL-STD-810G, Method 516.6, Procedure V, 40G, 11 ms, saw tooth, 3 shocks, +/- per axis

3,048 m (10,000 ft).

12,192 m (40,000 ft).

Maximum temperature is reduced by 1 °C/300 m (1 °F/547 ft) above 950 m (3,117 ft).

Maximum temperature is reduced by 1 °C/175 m (1 °F/319 ft) above 950 m (3,117 ft).

Maximum temperature is reduced by 1 °C/125 m (1 °F/228 ft) above 950 m (3,117 ft).

8

Page 8
Image 8
Dell R420xr Environmental Temperature Continuous Operation, Temperature Ranges for altitude less than 950 m, or 3117 ft