Anytime any maintenance or repairs are done (including clearing jams),

FIRST:

1.Disconnect the Nailer from the air hose.

2.Empty the Magazine (92) completely.

3.Attempt to fire the Nailer into a piece of scrap wood to ensure that it is discon- nected and is incapable of firing any nails.

Clearing Jams

1.Occasionally a nail may become jammed in the firing mechanism of the Roofing Nailer, making the tool inoperable.

2.To remove a jammed nail, disconnect the Roofing Nailer from its compressed air supply. Empty the Magazine (92) completely of nails. Attempt to fire the Roofing Nailer into a piece of scrap wood to ensure it is disconnected and is incapable of firing any nails.

3.Use a pair of needle nose pliers (not included) to remove the jammed nail (usu- ally from the Feed Pawl (61) area). Replace the coil of nails into the Roofing Nailer. Close the Magazine Cover (101) and Door (80) securely. Then, recon- nect the air supply hose to the tool.

Anytime any maintenance or repairs are done, FIRST:

1.Disconnect the Nailer from the air hose.

2.Empty the Magazine (92) completely.

3.Attempt to fire the Nailer into a piece of scrap wood to ensure that it is discon- nected and is incapable of firing any nails.

Inspection, Maintenance, and Cleaning

1.Inspect the Nailer frequently and lubricate periodically with Pneumatic tool oil, then wipe dry.