Unpacking
When unpacking, check to make sure all parts shown in the Parts List on page 13 are included. If any parts are missing or broken, please call Harbor Freight Tools at the number on the cover of this manual as soon as possible.
Operation
For best service, you should incorporate an oiler, regulator, and inline filter, as shown in the diagram below. Hoses, couplers, oilers, regulators, and filters are all available at Harbor Freight Tools.
TO
ROOFING
NAILER
Note: To connect this tool, we recommend you use the included quick connector. For smoother operation and to extend the
Testing the Contact Safety Trip Mechanism
Warning: Even though the nailer should be empty during this procedure, ALWAYS point the Nailer at a piece of scrap wood and wear ANSI approved safety goggles when testing.
1.Make sure the tool is disconnected from the air supply.
2.Completely empty the Magazine (92) of brads.
3.The Nailer should not fire if the Nose (72) is not depressed against the workpiece.
4.Make sure the Trigger (42) and Nose (72) move freely, without sticking - see the illustration on the following page.
SKU 41209 | For technical questions, please call | Page 6 |