5.Connect the air supply to the tool at the Air Plug (17). Set the regulator at the recommended 65 PSI to 100 PSI. Do not to go over the maximum 100 PSI.
6.Test the tool by depressing the nose against the workpiece without pulling the Trigger (42). The Tool must not cycle (fire). If it cycles (fires), stop immedi- ately and have it repaired by a qualified service technician.
7.Hold the tool away or off of the workpiece. The Nose (72) of the tool should return to its original position. Squeeze the Trigger (42). The tool should not cycle (fire). If the tool fires, stop immediately and have it repaired by a qualified service technician.
8.Depress the Nose (72) against the workpiece and squeeze the Trigger (42). The tool must cycle (fire). Release the Trigger and squeeze it again. The tool must cycle (fire). With the Trigger held, carefully lift the Nailer and press it against the workpiece again. The tool must cycle (fire). If it fails to perform in the manner explained in bold, have it repaired by a qualified service technician.
Loading Coil Nails
ALWAYS WEAR ANSI APPROVED IMPACT SAFETY GOGGLES WHEN RELOADING OR DOING ANY OTHER MAINTENANCE ON THIS TOOL. Other people in the work area must also wear ANSI approved impact safety goggles.
Warning! Make sure the Nailer is not attached to the air hose whenever loading the tool.
AIR PLUG (17)
TRIGGER (42)
NOSE (72)
SKU 41209 | For technical questions, please call | Page 7 |