support.dell.com Cluster SE300 and SL300 Platform Guide 1-7
 !"$$%


 !"
#$!
%
The following list provides PCI slot assignment information for buses, RAID control-
lers, NICs, and a DRAC.
PCI buses
PCI bus 1: PCI slots 1, 2, and 3 are 64-bit, 33-Mhz.
RAID controllers
RAID controllers can be installed in any available PCI slot.
If you use multiple RAID controllers and there are slots available, Dell recom-
mends installing the RAID controllers on separate PCI buses to balance the
load on the system.
If you are not currently using a DRAC and do not plan to use one in the
future, Dell recommends that you install one RAID controller in the 32-bit
slot, even if it is a 64-bit RAID controller.
NICs
You can install NICs in any available PCI slot.
Dell recommends that Giganet cLAN adapters be installed in 64-bit slots.
DRAC
PCI slot 2 is dedicated to interface with the optional DRAC.
NOTE: To make sure that the SCSI or RAID controller attached to the boot drives
initializes first, you might have to change the scan order of the PCI bus, if the BIOS
supports this option, or change the order of the RAID, NIC, and DRAC. Performing
these tasks ensures that the Windows operating system numbers the boot drives in
the proper sequence.
