Error Message

Description

Diskette subsystem reset failed

The floppy drive controller may be faulty.

Gate A20 failure

One or more memory modules may be faulty or improperly seated. Reinstall

 

the memory modules and, if necessary, replace them.

General failure

The operating system is unable to carry out the command. This message is

 

usually followed by specific information—for example, Printer out of paper.

 

Take the appropriate action to resolve the problem.

Hard-disk drive configuration error

The hard drive failed initialization.

Hard-disk drive controller failure

The hard drive failed initialization.

Hard-disk drive failure

The hard drive failed initialization.

Hard-disk drive read failure

The hard drive failed initialization.

Invalid configuration information-

The computer configuration information does not match the hardware

please run SETUP program

configuration.

Invalid Memory configuration, please

DIMM1 slot does not recognize a memory module. The module should be re-

populate DIMM1

seated or installed.

Keyboard failure

A cable or connector may be loose, or the keyboard or keyboard/mouse

 

controller may be faulty.

Memory address line failure at

A memory module may be faulty or improperly seated. Reinstall the memory

address, read value expecting value

modules and, if necessary, replace them.

Memory allocation error

The software you are attempting to run is conflicting with the operating

 

system, another program, or a utility.

Memory data line failure at address, read value expecting value

Memory double word logic failure at address, read value expecting value

Memory odd/even logic failure at address, read value expecting value

Memory write/read failure at address, read value expecting value

Memory size in CMOS invalid

A memory module may be faulty or improperly seated. Reinstall the memory modules and, if necessary, replace them.

A memory module may be faulty or improperly seated. Reinstall the memory modules and, if necessary, replace them.

A memory module may be faulty or improperly seated. Reinstall the memory modules and, if necessary, replace them

A memory module may be faulty or improperly seated. Reinstall the memory modules and, if necessary, replace them.

The amount of memory recorded in the computer configuration information does not match the memory installed in the computer.

Memory tests terminated by keystroke

A keystroke interrupted the memory test.

No boot device available

The computer cannot find the floppy disk or hard drive.

No boot sector on hard-disk drive

The computer configuration information in System Setup may be incorrect.

No timer tick interrupt

A chip on the system board might be malfunctioning.

Non-system disk or disk error

The floppy disk in drive A does not have a bootable operating system installed

 

on it. Either replace the floppy disk with one that has a bootable operating

 

system, or remove the floppy disk from drive A and restart the computer.

47

Page 47
Image 47
Dell T1650 owner manual Memory modules and, if necessary, replace them, General failure, Hard drive failed initialization

T1650 specifications

The Dell T1650 is a robust and versatile desktop workstation designed to meet the needs of professionals in various fields such as engineering, graphic design, and data analysis. Tailored for performance and reliability, the T1650 serves as a solid choice for those seeking a dependable computing solution.

One of the standout features of the Dell T1650 is its powerful processor options. Equipped with Intel's latest Core and Xeon processors, the workstation provides high processing power that can handle demanding applications and multitasking with ease. The T1650 supports a range of processors, allowing users to choose configurations that best suit their performance needs and budget.

Memory is another key aspect of the T1650, with support for up to 32GB DDR3 RAM. This substantial memory capacity allows for the smooth operation of resource-intensive software applications, which is essential for tasks like 3D rendering, video editing, and complex data manipulation. The flexibility in memory configuration enables users to optimize performance for specific workloads.

Storage options on the T1650 are equally impressive, featuring multiple drive bays for both traditional hard disk drives (HDD) and solid-state drives (SSD). Users can configure their systems for high-capacity storage or opt for faster SSD solutions to enhance overall system responsiveness and boot times. The inclusion of RAID support further ensures data redundancy and increased performance, catering to users with critical data storage requirements.

Graphics capabilities are another highlight of the Dell T1650, with the option to integrate high-performance discrete graphics cards from leading suppliers such as NVIDIA and AMD. This feature is particularly valuable for creative professionals who rely on advanced graphics rendering for their work.

The design of the T1650 emphasizes ease of use and accessibility, with a tool-less chassis that allows for simple upgrades and maintenance. The workstation also includes numerous ports and connectivity options, including USB 3.0, HDMI, and audio ports, ensuring that users have the connectivity needed for modern peripherals.

In summary, the Dell T1650 workstation is aimed at professionals seeking a dependable, high-performance system. With its powerful processor options, substantial memory and storage capabilities, and advanced graphics support, the T1650 stands out as an ideal choice for users in fields that demand reliability and efficiency in computing. Its design and upgradeability further enhance its appeal, making it a standout option in the workstation market.