3-Wire Conduit Installation
(See Figures 2.1, 2.7, 2.8 and 2.9)
1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 2.1).
2.Remove the Bracket and Strain Relief group by unscrewing the Bracket Fixing Screws (2.7).
3.Mount the Conduit Bracket (supplied with the range in a sep- arate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in Figure 2.8).
4.Feed 3/4” (1.90 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp (fig. 2.9).
5.Remove the 3 wire terminal nuts and washers from the Terminal Block.
6.Plug the terminal holes of conductors. The Neutral or Ground Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block. The Power Wires must be connected to the outside terminals.
7.Plug washers and tighten nuts securely.
Do not remove Ground strap.
8.Assemble the Terminal Block Access Plate.
(See Figures 2.1, 2.7, 2.8 and 2.10)
1.Remove the Terminal Block Access Plate on the back of the range by unscrewing the 4 fixing Screws (fig. 2.1).
2.Remove the Bracket and Strain Relief group by unscrewing the Bracket Fixing Screws (fig. 2.7).
3.Mount the Conduit Bracket (supplied with the range in a sep- arate kit) inside the Opening For Electrical Connection by screwing the 2 Fixing Screws (as indicated in figure 2.8).
4.Feed 3/4” (1.90 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp (fig. 2.10).
5.Remove the 3 wire terminal nuts and washers from the Terminal Block.
6.Remove the Ground Strap from the frame of range and ter- minal by removing its screw and cutting it as shown in fig- ure 2.10.
7.Plug the terminal holes of conductors. The Neutral Wire of the Power Cord must be connected to the neutral terminal located in the center of Terminal Block; the Power Wires
must be connected to the outside terminals; the Ground Wire must be attached to the frame of range by using the (Ground) identified Grounding Screw.
8.Plug washers and tighten nuts securely.
9.Assemble the Terminal Block Access Plate.
Fig. 2.7 |
Bracket |
Fixing Screws |
Bracket |
Strain Relief |
Fig. 2.8 |
Opening For |
Electrical |
Connection |
Fixing Screws |
Conduit |
Bracket |
Fig. 2.9
Terminal Block
Ground strap
Neutral Wire
Power Wires
Conduit Clamp
| Conduit | |
Conduit | Bracket | |
| ||
| Fig. 2.10 | |
Terminal Block | Cut Ground Strap | |
| Grounding Wire | |
Neutral Wire |
| |
Power Wires |
| |
Conduit Clamp | Grounding Screw | |
| ||
| Conduit | |
Conduit | Bracket | |
11 | ||
|