installation
PROXIMITY TO SIDE CABINETS
1.This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets.
Range dimensions:
•width: 23” 7/8 (606.5 mm)
•depth: 24” 11/64 (614.1 mm)
•height (without backguard): MIN 35” 17/32 (902.5 mm) - MAX 36” 7/32 (920 mm)
•backguard (height): 4” 7/16 (113 mm)
Grounded outlet should be located 7” 9/32 (185 mm) from the floor and from the rear left to the rear right side of the range.
2.The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (914 mm) high.
There must be a minimum of 3” (76 mm) side clearance from the range to such combustible surfaces TO THE LEFT above the 36” (914 mm) high countertop; or there must be a minimum of 3” (76 mm) side clearance from the range to such combustible surfaces TO THE RIGHT above the 36” (914 mm) high countertop.
IMPORTANT: One side (left or right) above the 36” (914 mm) high countertop must always be kept clear.
3.The maximum upper cabinet depth recommended is 13” (330 mm). Wall cabinet above the range must be a minimum of 30” (762 mm) above the countertop for a width of minimum 24” (609.6 mm): it has to be centred with the range. Side wall cabinets above the range must be a minimum of 18” (457 mm) above the coun- tertop.
MIN 35" 17/32 (902.5 mm) 4" 7/16
MAX 36" 7/32 (920 mm) (113 mm)
24" |
| |
(614. | 11/64 | |
1 | ||
mm) | ||
|
23" | 7/8 | ||
| mm) | ||
.5 | |||
| |||
(606 |
|
|
Fig. 1.1
ELECTRIC CONNECTION
7" 9/32 (185 mm)
Fig. 1.2
Dotted line showing the position of the range when installed
Area for electric connection
5